Section 8 Setting data
Function
Setting
Function
Setting
Function
Setting
8-4
• Initial setting protect
Restricts movement to the Input initial setting, Control initial setting,
Control initial setting 2, Alarm setting, Display adjustment, and
Communication setting level.
Setting
Move to Input initial
values
setting level
Yes (shows "Advanced
0
function setting level")
Yes (Does not show
1
"Advanced function
setting level")
2
No
• When "Initial setting level protect" is set to "2", nothing happens
when the level key is held down for 1 second to move to Input initial
setting level from Operation, Adjustment, Adjustment 2, Bank
setting, PID setting, Approximation setting, or Monitor item level.
(The blinking display to indicate the move does not appear.)
• Setting change protect
Prevents use of the UD keys.
Setting
Change settings by key
value
operation
OFF
Yes
ON
No
• "Setting change protect" is initially set to "OFF".
• PF key protect
Prevents use of the PF1/PF2 keys.
Setting
Change settings by key operation
value
OFF
PF1/PF2 keys are enabled
PF1/PF2 keys are disabled (operation as a function key and
ON
channel key is disabled)
• "PF key protect" is initially set to "OFF".
Move to Control initial setting,
Control initial setting 2, Alarm
setting, Display adjustment, and
Communication setting level
Yes
Yes
No
Remarks (exceptions)
• All setting data on Protect level
• "Move to special function level"
• "Move to calibration level"
• "Display bank selection"
• "Display PID selection"