Table of Contents
Table of Contents
8
User Manual
1
Conventions Used in this Manual
4
Chapter 1 Introduction
6
Chapter 2 Preparations
6
Chapter 3 Basic Operation
6
Chapter 4 Applied Operation
6
Troubleshooting
6
Pay Attention to the Following When Installing this Controller
7
Table of Contents
8
Names of Parts
11
Main Parts
11
Front Panel
11
About the Displays
12
How to Use Keys
12
Input and Output
13
Parameters and Menus
16
Parameter Types
16
Selecting Modes
17
Menu Display
17
Selecting Parameters
18
Fixing Settings
18
Manual Mode
18
About the Communications Function
19
About Calibration
20
Setting up
23
Setting up the Output Unit
24
Setting up the Option Unit
25
Before Setup
25
Panel Cutout
26
Setting up the Terminal Covers
28
Terminal Arrangement
29
Power Supply
29
Chapter 3 Chapter 3 Basic Operation
34
Basic Operation
35
Convention Used in this Chapter
35
Setting Input Specifications
37
Input Type
38
Setting Output Specifications
39
Output Assignments
39
Direct/Reverse Operation
39
Control Period
39
Setting Alarm Type
42
Alarm Type
42
Alarm Value
43
Alarm Hysteresis
43
Alarm Hysteresis
44
Close in Alarm/Open in Alarm
44
Protect Mode
45
Security
45
A/M Key Protect
45
Starting and Stopping Operation
46
Adjusting Control Operation
47
Changing the Set Point
47
Chapter 4 Chapter 4 Applied Operation
52
Manual Operation
53
Selecting the Control Method
53
Heating and Cooling Control
53
Position-Proportional Control
54
ON/OFF Control
54
Operating Condition Restrictions
56
Set Point Limiter
57
Sp Ramp
57
Manipulated Variable Restrictions
58
SP Ramp
58
How to Use Event Input
59
Event Input Assignments
59
Multi-SP
59
Other Event Input Functions
61
How to Use the Remote SP
62
Scaling
62
SP Mode
63
Remote SP Monitor
63
SP Tracking
63
Operating Conditions
63
How to Use the Heater Burnout Alarm
64
Heater Burnout Detection
65
The Heater Burnout Set Value
65
Lba
66
Lba Detection Time
67
How to Use Transfer Output
68
About Parameter Display
71
Conventions Used in this Chapter
71
A/M] Key Protect
73
Manual Mode
74
Manual MV
74
Remote Sp Monitor
76
MV Monitor (Heat)
77
Set Point During Sp Ramp
77
At Execute/Cancel
80
Set Point
80
Integral Time
82
Proportional Band
82
Dead Band
83
Hysteresis (Heat)
84
Manual Reset Value
84
Heater Burnout
86
Heater Current Monitor
86
Sp Ramp Set Value
89
MV at Pv Error
90
MV Change Rate Limit
91
Input Digital Filter
92
Chapter 5 Parameters
95
Setup Mode
96
Decimal Point
96
Parameter Initialize
96
Control Output 2 Assignment
97
Auxiliary Output 1 Assignment
98
Auxiliary Output 2 Assignment
98
Alarm 1 Type
99
Alarm 2 Type
99
Direct/Reverse Operation
100
Set Point Upper Limit
102
Set Point Lower Limit
102
Standby Sequence Reset Method
104
Automatic Return of Display Mode
105
Event Input Assignment
108
Transfer Output Upper Limit
110
Transfer Output Lower Limit
110
Remote Sp Lower Limit
113
Chapter 6 Chapter 6 Using the Communications Function
116
Communications Function
116
Outline of the Communications Function
117
Cable Connections
118
Preparing for Communications
118
Setting the Communications Specifications
119
Command Configuration
120
Commands and Responses
121
Reading/Writing Parameters
121
Command List
125
Issuing Special Commands
125
How to Read Communications Error Information
127
End Code
127
Undefined Error
128
Conditions When Running a Program
129
Examples of Use
131
Set the Set Point to
131
How to Use Programs
129
Program Example
129
Start Running
131
Structure of Parameters
133
Calibrating Thermocouple
135
Chapter 7 Calibration
138
Calibrating Platinum Resistance Thermometer
138
Calibrating Current Input
140
Calibrating Voltage Input
141
Checking Indication Accuracy
143
Initial Checks
147
How to Use the Error Display
148
Input Error
148
Memory Error
148
Calibration Data Error
149
Display Range over
149
How to Use Error Output
150
Checking Operation Restrictions
151
Appendix
152
Specifications
153
Heter Burnout Alarm
154
About Current Transformer (Ct)
156
Control Block Diagram
157
Standard Type
157
Setting List
159
Model List
162
Parameter Operations List
163
Fuzzy Self-Tuning
165
Balanced Status
166
Stable Temperature Status
166
Startup Conditions of Dt
167
Startup Conditions of Ht
167
Format
168
X Format Head List
169
Ascii Code List
171
Symbols
172
Chapter 8 Troubleshooting
176
Revision History
176
Revision Code
176
Advertisement
Advertisement
Related Products
Omron E5AK-AA2 AC/DC24
Omron E5AK-AA2-500 AC/DC24
OMRON E5AK
Omron E5AK-PRR2 AC100-240
Omron E5AK-PRR2 AC/DC24
Omron E5AK-T
Omron E5AK-PRR2-500 AC/DC24
Omron E5AK-TAA2
Omron E5AK-TAA2-500
Omron E5AK-TPRR2
Omron Categories
Blood Pressure Monitor
Controller
Accessories
Switch
Inverter
More Omron Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL