CLEANING

1. CLEANING UNIT REMOVAL

1. Raise the development lock lever and pull
out the development unit. Place the unit on
a clean sheet of paper.
2. Swing the toner collection bottle cover [A]
to the left (1 screw) and unplug the toner
overflow sensor connector [B].
3. Remove the toner collection bottle [C].
4. Lower the T/S corona unit [D].
5. Place a sheet of paper [E] over the T/S
corona unit.
6. Remove the charge corona cover [F] (1
screw).
7. Unplug the charge corona connectors [G]
and remove the charge corona unit [H].
8. Remove the pre-quenching corona unit [I].
9. Remove the drum stay [J] (knob and 1
screw).
10. Slide out the cleaning unit [K].
CAUTION: Be sure the pick-off pawls are kept
away from the drum when removing
the cleaning unit or serious drum
damage will result.