2. Installation
19. Connect the PCB harness connector [A] to CN135 of the finisher PCB and to CN600 of the punch
unit PCB.
20. Connect the harness [B] to CN136 of the finisher PCB.
21. Connect the single end of the hopper full sensor connector cable [C] to the hopper full sensor on
the arm (
• No special DIP switch settings are required for this punch unit. A signal from the punch
identifies itself by sending a signal to the copier.
22. Reattach the harness cover [A] ( x 2) and middle cover [B] ( x 2).
200
x 1,
x 2).