Configuration of the host

You can make the network settings in the "Host Settings" tab and permanently save this
configuration, in contrast to the settings in the "Network Settings" dialog box of the Service
Center.
Settings that you make in this dialog box are stored in the servicesystem.ini configuration
file.
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB
Adapter settings - Ethernet 1 (company network)
Purpose
Select the Ethernet interface that you want to configure.
All settings in this dialog box refer to the selected Ethernet interface.
Select whether the values set in the Control Panel are to be used.
Select whether the addresses are to be fetched dynamically from the DHCP server.
If the checkbox is deactivated, you must make the settings manually.
Set the IP address of the NCU.
You can specify an IP address from the following range:
192.168.214.250 - 254
Specify a subnet mask, e.g. 255.255.255.0
Set the IP address of the standard gateway.
A standard gateway creates a standard route in the IP routing table for all destinations that are not
in the subnet.
Set the IP address of the name server.
A name server answers questions asked about a domain name zone using a DNS database.