Configuring Routing In The Network - Siemens SINUMERIK MC Commissioning Manual

Mcu commissioning: nc, plc, drive
Hide thumbs Also See for SINUMERIK MC:
Table of Contents

Advertisement

Figure 10-17
Basic procedure
On the PG/PC with Windows 10:
● Connecting a PG/PC to a Siemens PC system according to one of the configurations shown
above.
● The network protocol used is: TCP/IP.
TCP/IP is already pre-configured on the Siemens PC system.
● Setting up IP addresses on the same subnetwork.
● Sharing a directory on the PG/PC for network access.
On the Siemens PC system in the Service Center:
● Start the Service Center on the IPC.
● Establish a network connection to the shared directory of the PG/PC.
Further information: Functions of the Service Center (Page 246)
10.5.12.3

Configuring routing in the network

Overview
If you have connected a PG/PC at the NC interface X127 of the MCU, configure the network
routing to establish the connection between the PG/PC and the IPC.
Figure 10-18
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB
Connecting a PG/PC at the IPC via a switch
A networking example using IP routing
Installing and setting up PCU Base for IPC
10.5 Backing up and restoring data
263