"Create archive" view
Parameter
Header
NCU components
Storage path
Archive name
Created by
Comment
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB
Creating and importing archives using SINUMERIK Commissioning
8.3 Creating a DSF archive on SINUMERIK MC
Remark for configuration
The header shows the selected archive type.
Selected components to be written to the archive:
● NCK
● PLC
● Drives
● NCextend
A progress display appears for each selected component during the
archive creation.
Once all components have completed their action, the status of each
component is displayed.
The archive is saved when all components have stored their data
correctly.
If any errors occur, even only for a single individual component, the
archive is not saved. The error log is displayed.
The archive path is preassigned, but can be changed with the
"Change storage path" softkey.
The system suggests a generic archive name. The generic archive
name is formed from:
● Archive type (e.g. Backup)
● Abbreviation for selected components:
NCK: N
PLC: P
Drive: D
NCextend: L
● Date (ISO)
● Possibly an extension (1, 2, 3, etc.)
Example
Backup_NL_2019-06-03
Backup_NPD_2019-06-03_1
Note
The generic archive name does not make any distinctions in the HMI
runtime environment (PC, IPC, ...).
The "original.dsf" archive name for restoring the factory setting can‐
not be changed.
Input field for the creator as well as the creation date of the archive
(optional).
Input field for possible comments regarding the archive (optional).
167