Via the Control Panel
Procedure
To activate remote access from the PG/PC in the company network to the Siemens PC system,
proceed as follows:
1. Enter "Control Panel" in the search field and then click on "Control Panel" in the search
results.
The desktop App "Control Panel" opens.
2. Click on the display selection and switch from the "Category" view to "Icons".
The "All Control Panel Items" dialog box opens.
3. Click on "Windows Defender Firewall".
4. Click on "Advanced settings" and confirm the call of the expanded settings with "Yes" if
necessary.
5. In the "Windows Firewall with Advanced Security" dialog, right-click under "Inbound Rules"
on the rule "vnc5900", then click on "Enable Rule".
Result
With the activation of the inbound rule "vnc5900", Port 5900 was activated in the company
network, which allows remote access from a PG/PC to the Siemens PC system in the company
network.
If you want to deactivate remote access in the company network, right-click on the rule
"vnc5900" and select "Disable Rule" in the shortcut menu.
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB
Installing and setting up PCU Base for IPC
10.3 Configuration of the system