Siemens SINUMERIK MC Commissioning Manual page 139

Mcu commissioning: nc, plc, drive
Hide thumbs Also See for SINUMERIK MC:
Table of Contents

Advertisement

3. Under "General", click "PROFINET Subnet > Domain management > Sync domains > Sync-
Domain_1".
4. Check the settings, in particular, the assignment of the devices in the "IO devices" section,
and complete where necessary.
Check the PROFINET port interconnection
In the topology view, you see an overview of all ports in the project and can interconnect them
centrally.
To edit the properties of the port interconnection, proceed as follows:
1. Switch to the topology view.
Note
If you hover the mouse over the ports, port names are displayed in the tooltip.
2. Select the port with which the drive is connected to the control.
The port settings are displayed in the Inspector window.
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB
Commissioning NC-controlled drives
6.3 Commissioning drives via device master files
139