Siemens SINUMERIK MC Commissioning Manual page 240

Mcu commissioning: nc, plc, drive
Hide thumbs Also See for SINUMERIK MC:
Table of Contents

Advertisement

Installing and setting up PCU Base for IPC
10.4 Installing and configuring updates and automation software
Section
Setting
[processing_
StartState=
systemphase]
scanSetupDirs=
scanRemovableDrive
SetupDirs=
scanNetworkDrive
SetupDirs=
numberOfScanCycles
waitTimeBetween
ScanCycles
report
InfoLevel
240
Description
Specifies whether the PCU Installer is active during operation of the Desktop.
Possible values:
PCU Installer starts setups
activated
PCU Installer is stopped completely
stopped
You can define exceptions in Section [noactivation].
Specifies whether setup directories are to be checked and, if required, setup files
executed during Desktop operation.
The following directories are checked if this setting has been activated:
Local setup directories from the [local_setupdirs] setting are always checked.
You can define separately whether additional directories on removable data stor‐
age media or in the network are to be checked. (See settings "scanRemovable‐
DriveSetupDirs" and "scanNetworkDriveSetupDirs")
If you deactivate this setting, neither local directories, nor directories on removable
data storage media or in the network are checked, i.e. the setting scanSetupDirs=no
overwrites, for example, scanNetworkDriveSetupDirs=yes.
Possible values: yes; no
Specifies whether directories on removable data storage media are to be checked from
the setting [removable_setupdirs] and, if required, setup files executed during Desktop
operation.
The setting "scanSetupDirs" must also be activated so that these directories are
checked.
Possible values: yes; no
Specifies whether network directories are to be checked from the setting [net_setup‐
dirs] and, if required, setup files executed during Desktop operation.
The setting "scanSetupDirs" must also be activated so that these directories are
checked.
Possible values: yes; no
Specifies whether and how often the setup directories check for new setup packages.
Possible values:
Infinite
infinite
Integer
You can define the waiting time between checks in
key waitTimeBetweenScanCycles
Specifies how long the PCU Installer waits after the setup directories have been
checked before checking them again.
Enter the waiting time in milliseconds.
In key numberOfScanCycles, you can specify how often the setup directories will be
checked.
Specifies how detailed the information is to be which is stored in the log files.
Possible values:
1: Only basic information on the actions of the PCU Installer is logged
2: All PCU Installer-specific information is logged
3: All PCU Installer-specific information and some trace information is logged
4: All PCU Installer-specific information and additional trace information is logged
5: All PCU Installer-specific information and all trace information is logged
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB