Installing and setting up PCU Base for IPC
10.5 Backing up and restoring data
3. Make the required settings here:
4. To start the restore process and entirely replace the existing data on the SSD with the disk
image, confirm the settings with "Restore".
Result
The restore process is started.
Note
Troubleshooting if reading in of the disk image fails
If data transfer is interrupted during the restore process, the PC system will have no executable
system.
In this case, use a bootable USB flash drive with Service Center to read the disk image in again.
254
Section
Setting
Base parame‐
Source file
ters
Destination disk Select the SSD to be restored from the disk image.
Base parame‐
Connect share
ters > Destina‐
tion disk
Select source
Optional pa‐
Adjust partitions No MCU setting, only PCU 50.x:
rameters
Change ma‐
chine SID and
Computer
Name
Purpose
Select the disk image from which the SSD is to be restored.
You can use local disk images or disk images stored in the net‐
work.
Open the "Connect a Share" dialog box (Page 258).
You can manage a shared resource (e.g. a directory in the net‐
work), to use a disk image stored on the network to restore the
SSD.
Open the "Select Source File" dialog box.
You can navigate through a local directory of the PC system and
select a disk image for restoration.
Select the partition scheme to be used when restoring the disk
image on a PCU 50.x:
● If the PCU-Basesoftware Windows 7 is on the disk image,
choose "PCU Base Windows 7 partition scheme".
● If the PCU-Basesoftware Windows XP is on the disk image,
choose "PCU Base Windows XP partition scheme".
It is not possible to use a different operating system on a Sie‐
mens PC system other than the pre-installed system (e.g. Win‐
dows XP running on a Windows 10 IPC).
If you are using a different PC system than the PCU 50.5, you
must deactivate the "Adjust partitions" setting.
No MCU setting, only Windows XP:
After restoring the image, changes the computer name and the
computer SID. This option is only available if the Windows XP
partition schematic was selected.