NC commissioning
7.3 Configuring machine axes
Assignment:
1. Using this machine data, the NC is informed about the I/O addresses of the SERVO drive
objects defined in the PLC project:
MD13050 $MN_DRIVE_LOGIC_ADDRESS[n]
2. Using the following machine data, the setpoint and actual values of the machine axes are
assigned to the relevant drive objects:
– MD30110 $MA_CTRLOUT_MODULE_NR[0]
– MD30220 $MA_ENC_MODULE_NR[0]
The logical drive number m to be entered into both machine data, refers to the I/O address
entered in
3. Using machine data MD10000 $MN_AXCONF_MACHAX_NAME_TAB, the machine axes
in the NC are assigned a unique name. Index n addresses machine axis (n+1).
154
under index n = (m - 1).
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB