General preparation Structure Settings, MPI/BTSS EMC/ESD measures SINUMERIK 840D/810D Power-On and Power-Up SIMODRIVE 611 digital Programming the control Start-Up Guide PLC description Alarm and message texts Axis/spindle test run Drive optimization Data back-up Replacing software and hardware Miscellaneous Valid for Control Version SINUMERIK 840D/810D powerline...
Page 2
® All designations identified with the trademark note are registered trademarks of Siemens AG. The other designations in this publications may be trademarks, the use of which by third parties for their own purposes may infringe the rights of the owner.
Page 4
Internet: http://www.ad.siemens.com/csinfo under product/order number 15257461 from the responsible branch of the A&D MC Division of Siemens AG Object of the book The publication illustrates the structure of the control system and the interfaces to the individual components. It also describes the procedure for starting up SINUMERIK 810D, and lists all the data, signals and PLC modules.
Warning The device must only be used for the purposes described in the catalog and in the technical description, and then only in conjunction with non-Siemens devi- ces and components that are recommended or approved by Siemens. Correct and safe operation of the product requires it to have been transported, stored, installed and assembled correctly and carefully operated and maintained.
(control, power section, machine). The signal and load cables must be kept as far apart as possible. Only original SIEMENS cables should be used as the signal cables from and to the NCK and PLC.
0 to 3 or passwords for end users through to Siemens, as shown in Table 6-2. To allow the programs stored in the cycle directories to be used via a range of commands that are independent of the rights of use of a particular operator, the right of use is implicitly modified while these programs are running.
A logical address via which the relevant drive is addressed (setpoint/actual value assignment, access to parameters) is assigned to each slot used. Siemens AG 2006 All Rights Reserved 6-82 SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition...
To avoid setting the MSD parameters incorrectly, the “OK” soft key remains disabled until a valid motor or a non-Siemens motor is selected for motor 1. After selecting the motor, press the “OK” soft key to confirm and a menu for entering the encoder data appears.
Page 88
Non-Siemens motor If a non-Siemens motor is used, press the “Non-Siemens motor” soft key to open the menu for entering the non-Siemens motor data. When you have ent- ered the data and returned to the motor selection menu, “Non-Siemens motor”...
– Select drive type: “SLM” (synchronous linear motor) ––> Add module – Select the power section Fig. 6-24 Drive configuration for synchronous linear motor Siemens AG 2006 All Rights Reserved 6-131 SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition...
Page 133
If yes: Select the motor (parallel-connected linear motors start with 2x1FN..) Fig. 6-26 Selecting a motor for which the data is already listed Siemens AG 2006 All Rights Reserved 6-133 SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition...
Page 135
“Coarse synchronization with” field: – Rotor position identification: yes (for incremental measuring system only) Confirm acceptance of data with OK ––> “Save bootfile” and select “NCK reset”. Siemens AG 2006 All Rights Reserved 6-135 SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition...
Page 136
The traversing range must be kept clear of obstacles at all times to protect operating personnel and the machine itself. Siemens AG 2006 All Rights Reserved 6-136 SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition...
Page 139
Note With non-Siemens motors, the rotor position identification method cannot be guaranteed to determine the commutation angle offset. Depending on the design of the motor, the following methods may be used for both types of...
Page 140
Is the distance traversed correct? (input = 10 mm ––> distance = 10 mm) 10. Set and perform referencing/adjustment – Incremental measuring system: Referencing (see subsection 6.9.12) – Absolute measuring system: Adjust (see subsection 6.9.6) Siemens AG 2006 All Rights Reserved 6-140 SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition...
Page 142
– Select the paralleled motor from the “Motor selection” dialog. (2x1FN..) or: Enter the data for the paralleled non-Siemens motor (as described under the heading of “Non-Siemens motors – parameters for SLM”). 16. Compare the commutation angle offset between motor 1 and 2 –...
Note The instructions for determining the drive direction apply only to Siemens motors (1FNx motors). If the positive direction of the drive and the positive counting direction of the measuring system do not coincide, then the actual speed value must be in- verted in the “Measuring system/Encoders”...
PC/PG (as described in chapter 12). Alarm texts/ The texts are stored with the Siemens defaults n the selected drive on your PC. message texts For the sake of simplicity, it is assumed that this is always C: in the following description.
Page 168
HMI Advanced only (PCU 50/ 50.3/ 70, with hard disk): The default assignment of “0” means that the WinHelp file supplied by Siemens gives a detailed explanation of the alarm. A value between 1 and 9 refers to a WinHelp file created by the user via an allocation table in the MBDDE.INI file.
Page 170
FIRST means that more recent alarms are placed at the top of the list, LAST means that new alarms are placed at the end. PLCTIME Siemens internal variable for PLC software releases older than 3.2. Do not change the PLCTIME setting. Example: [Alarms] TimeFormat=%d.%m.%y %H:%M:%S...
Loading of master images (images for series start-up) remains with the ma- chine manufacturer. Upgrading or downgrading can be executed by the machine manufacturer (master image) irrespective of what is supplied by Siemens. The Norton Ghost back-up program is installed on every PCU.
Page 246
PG/PC parallel cable PC/PG with bidirectional interface, EPP setting LapLink–Siemens parallel cable (Order no. 6FX2002-1AA02-1AD03) com- mercial LapLink cable For PCU, set the parallel port to EPP (Bios), which will increase the trans- mission speed of the parallel interface by approximately 10%.
The VALITEK streamer is connected to the parallel port X8 (25-pin) on the connection PCU 50/70 using only the SIEMENS cable 6FC9 344-4xV. No other data back-up device can be connected since the software is designed to operate with the VALITEK streamer.
2. The machine manufacturer can provide the cycles and data in the archive on the NC card when he supplies the machine or a software upgrade. You have the option of transferring Siemens and/or machine manufacturer cycles from the flash file system on the NC card to the DRAM when the control powers up and running them from there.