4. Confirm the download with "Load".
The "Download preview" dialog opens.
Note
Consistency check
Before the loading, the consistency of the download is checked. This means that a check is
performed as to whether the parameterized hardware of the TIA Portal project matches the
hardware that has actually been installed.
Note
Adapt the IP address?
If the IP address of your PG/PC is located in a different subnet than the IPC, a dialog box is
displayed indicating whether the IP address in the PG/PC should be adapted.
5. In the "Download preview" dialog, check the settings and click "Load" to confirm the input.
Result
The software configuration is loaded to the IPC. The "Results of the loading action" dialog
opens and displays the status of the loading action.
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB
PLC commissioning
5.3 Configuring the PLC
63