Installing and setting up PCU Base for IPC
10.3 Configuration of the system
Procedure
Proceed as follows to change the delay time:
1. Call the settings of the SITOP software, for example, by right-clicking the SITOP UPS icon
in the information area and then selecting "Configuration".
2. In the "SITOP DC UPS Configuration" dialog box, enter the wait time in seconds as a
command line parameter in the "Buffering" tab:
– Syntax: <path>\USVShutdown.bat -<time in seconds>
– Example: C:\Program Files (x86)\Siemens\MotionControl\siemens
Figure 10-1
3. Confirm the setting with "Save".
Configuring SITOP UPS Manager (Ethernet)
Precondition
● The SITOP UPS hardware is connected via the Ethernet interface.
● The SITOP-UPS Manager has been installed and configured for Ethernet.
Note
Validity of the information on the SITOP components in this manual
This information only involves the configuration of the settings relevant for PCU Base. In
addition, all the information and notes in the corresponding manuals of your SITOP UPS
hardware and SITOP UPS Manager apply.
196
\sinumerik\hmi\base\USVShutdown.bat -180
SITOP Monitor Floating operation
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB