Before you adapt the settings in this file, you should copy the original file.
Section
Setting
[IPC]
FirewallSettings=
InstallWin10Updates=
TestSystemEnglish=
[SetupControl]
FinalReboot=
10.2.3

Installing PCU Base for IPC

You can install the PCU Base for IPC on the supported SIMATIC IPC configurations
(Page 175) (using an installation medium that can be individually ordered and licensed).
In the Industry Mall you can find the PCU Base for IPC under the following article number:
● 6FC5800-0AP86-0YB0
Precondition
● You can connect an operator panel front or screen and keyboard directly to the PC system.
● The commissioning of the PC system is completed and an administrator account is set up.
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB
Description
● 1 (default setting)
The Windows firewall settings are adapted appropriately for the com‐
pany network by the PCU Base for IPC, as described in this documen‐
tation.
● 0
The current firewall settings are not changed by the setup.
● 1 (default setting)
During setup of the PCU Base for IPC, important Microsoft Windows
updates are installed that are required for the use of the PCU Base. If
these updates cannot be installed, the setup of the PCU Base is can‐
celed.
● 0
The setup does not check whether the Microsoft Windows updates,
required for the PCU Base for IPC, have been installed or can be in‐
stalled. This setting may be required when new updates have already
been installed on the PC system, for example.
● 1 (default setting)
The setup checks whether an English Windows version has been in‐
stalled.
● 0
The setup does not check the Windows language version. In this case,
there is an additional prerequisite that the names of the network adapt‐
er do not, for example, contain a hyphen.
Note that this setting is only suitable for test purposes.
PCU Base for IPC is only compatible with English Windows versions.
● 1 (default setting)
The PC system is restarted after installation.
● 0
The setup does not restart the system or call a dialog after the instal‐
lation as to whether a restart is to be performed (supervised installa‐
tion).