Configuration / address space

5.1

Configuration of the TM NPU

The TM NPU can be configured with STEP 7 (TIA Portal) as of V16 with HSP 0333 and GSDML:
• Central deployment
– S7-1500 CPUs: as of V2.5
• Distributed deployment
– Interface Module IM 155-5 PN HF (6ES7 155-5AA00-0AC0): V3.0 or higher
– Interface Module IM 155-5 PN ST (6ES7 155-5AA01-0AB0): as of V4.1
Configuration of the TM NPU
You specify the properties of the module while configuring the module with STEP 7:
• Start address of the inputs
• Start address of the outputs
• Enable/disable load voltage diagnostics
• Enable/disable Gigabit Ethernet interface
• Enable/disable USB interface
Note
When configuring the TM NPU, note that either only the Gigabit Ethernet interface or the USB
interface can be enabled. Simultaneous activation of both interfaces is not possible and is
rejected by the module with a parameter assignment error.
You can find a configuration example of the TM NPU in the description of the application
example. You can obtain the application example from your SIEMENS representative.
Technology Module TM NPU
Equipment Manual, 09/2020, A5E46384784-AA