Sign In
Upload
Manuals
Brands
Comtech EF Data Manuals
Modem
SNM-1001L
Comtech EF Data SNM-1001L Manuals
Manuals and User Guides for Comtech EF Data SNM-1001L. We have
1
Comtech EF Data SNM-1001L manual available for free PDF download: Installation And Operation Manual
Comtech EF Data SNM-1001L Installation And Operation Manual (344 pages)
Brand:
Comtech EF Data
| Category:
Modem
| Size: 6.79 MB
Table of Contents
Table of Contents
7
Ac Power Connector
4
Installation and Operation Manual
5
Customer Support
6
Table of Contents
7
About this Manual
18
Related Documents
18
Electrical Safety
20
Telecommunications Terminal Equipment Directive
21
EMC (Electromagnetic Compatibility)
22
Warranty Policy
23
Limitations of Warranty
23
Chapter 1. Introduction
25
Overview
25
Options Summary
26
Figure 1-1. Block Diagram
26
Comtech EF Data Part Numbers
27
FAST Accessible Options
28
Table 1-1. Fast Options and Required Configurations
28
Compatibility
29
Description of the Modulator
29
Overview
29
Functional Description
29
Description of Modulation Types
30
Bpsk Encoding
31
Psk Encoding
32
Description of the Demodulator
33
Overview
33
Figure 1-2. Demodulator Block Diagram
33
Functional Description
34
Description of Monitor & Control
35
Overview
35
Functional Description
36
Figure 1-3. M&C Block Diagram
36
Dimensional Envelope
38
Figure 1-4. Dimensional Envelope Drawing
38
New in this Release
39
Chapter 2. Installation/ Upgrades
41
Unpacking
41
Installation
42
Modem Installation (Optional)
42
Software and Hardware Installation/Upgrades
44
Reed-Solomon PCB
44
Figure 2-2. Reed-Solomon Codec Installation
45
Turbo Codec Installation
46
Figure 2-3. Turbo Codec Installation
47
Data I/O Interface Connector (J8) Removal/Installation
48
Hardware Upgrades
49
Main PCB Firmware Chips
49
Figure 2-5. Main Board Field-Changeable Chips (Shown with Overhead Card Removed)
50
Flash Upgrading
51
2.6.1 Downloading Flash Updates from the Web
52
How to Download Flash Upgrade Files
52
How to Perform a Flash Upgrade
52
Chapter 3. Connector Pinouts
53
Connector Overview
53
Figure 3-1. Rear Panel
53
Table 3-1. Modem Rear Panel Connectors
54
Connector Description
55
Remote Connector and Pinouts (J6)
55
Fault Connector and Pinouts (J7)
56
Table 3-3. Fault Connector and Pinouts (J7)
56
Data I/O Interface Connector (J8)
57
Table 3-4. 25-Pin D Connector Pinouts
58
Table 3-5. 34-Pin Winchester Connector Pinouts (V.35)
59
Table 3-6. 37-Pin Connector Pinouts (Optional)
60
Auxiliary 1 Connector and Pinouts (J9)
61
Alarms Connector and Pinouts (J10)
62
RF Output Connector (CP1)
62
External Reference (CP2)
62
RF Input Connector (CP3)
62
Table 3-8. Alarms Connector and Pinouts (J10)
62
AC Power Connector
63
Ground Connector (GND)
63
Chapter 4. Front Panel Operation
65
Front Panel
65
Figure 4-1. Front Panel View
65
Status • Alarms the Indicators Are Defined in Table 4-1 as Follows
66
Table 4-1. Led Indicators
66
Front Panel Keypad
67
Figure 4-2. Keypad
67
Menu System
68
Revision Emulation
69
Front Panel Operation
70
Menu Tree
70
Figure 4-3. Menu Tree
70
Opening Screen
71
Function Select: Configuration
71
Tx-If Frequency
74
Tx Terminal Frequency
74
Tx-If Output
75
Diff. Encoder
76
Carrier Mode
77
Modem Reference
77
Fsk Output
78
Odu Power Supply
78
Odu Output Delay
79
Odu 10 Mhz Ref
79
Rs Encoder
80
Rx Terminal Frequency
83
Diff. Decoder
84
Rf Loop Back
84
Figure 4-4. Rf Loopback
85
If Loop Back
85
Figure 4-5. if Loopback
86
Ber Threshold
86
Sweep Center
87
Sweep Range
87
Lnb Power
88
Lnb Voltage
88
Lnb 10 Mhz Ref
89
Rs Decoder
89
Tx Clock Source
90
Tx Clock Phase
91
Buffer Clock
92
Rx Clock Phase
92
Figure 4-6. Baseband Loopback
93
Figure 4-7. Interface Loopback
94
Intrfc Loop Back
94
Buffer Size
95
Buffer Center
95
Loop Timing
96
Tx Data Fault
96
Nominal Power
98
Minimum Power
98
Maximum Power
99
Tracking Rate
100
Local Cl Action
100
Remote Cl Action
101
Function Select: Configuration: Save
101
Function Select: Configuration: Recall
102
Function Select: Monitor
102
Function Select: Monitor: Corrected Ber
103
Function Select: Monitor: Receive Signal
103
Function Select: Monitor: Sweep Frequency
104
Function Select: Monitor: Lnb Current
105
Function Select: Monitor: Lnb Voltage
105
Function Select: Monitor: Odu Current
106
Function Select: Monitor: Odu Voltage
106
Function Select: Faults/Alarms
109
Function Select: Faults/Alarms: Modulator
110
Function Select: Faults/Alarms: Demodulator
110
Function Select: Faults/Alarms: Tx Interface
111
Function Select: Faults/Alarms: Rx Interface
111
Function Select: Faults/Alarms: Outdoor Unit
112
Function Select: Stored Flts/Alms
113
Function Select: Remote Aupc (Conditional)
118
Tx 2047 Pattern
120
Function Select Utility
121
Function Select: Utility: Modulator
122
Mod Power Offset
126
Function Select: Utility: Modulator: Modulator Type
126
Function Select: Utility: Modulator: Encoder Type
126
Tx Bpsk Ordering
127
Function Select: Utility: Modulator: Mod Spectrum
127
Tx-Rs N/K Deep
128
Function Select: Utility: Modulator: Tx Mode
128
Rf Mode Control
129
Function Select: Utility: Modulator: Tx Symbol Rate
130
Function Select: Utility: Demodulator
130
Function Select:utility: Demodulator: Rx Terminal lo
133
Demodulator Type
134
Descrambler Type
135
Function Select: Utility: Demodulator: Rx Mode
135
Max Packet Size
136
Rx-Rs N/K Deep
136
Rx Symbol Rate
138
Function Select: Utility: Interface
138
Tx Overhead Type
138
Rx Overhead Type
138
Function Select: Utility: Interface: Buffer Program
139
Rts Tx-If Cntrl
139
Function Select: Utility: Interface: Tx Data Phase
139
Function Select: Utility: Interface: Rx Data Phase
140
Function Select: Utility: Interface: Cts Delay
140
Function Select: Utility: Outdoor Unit: Odu Fsk Address (Conditional)
141
Odu Fsk Address
141
Odu Output Power
141
Odu Pwr Leveling
142
Function Select: Utility: System: Remote Baud Rate
143
Function Select: Utility: System: Remote Address
143
Function Select: Utility: System: Remote Type
143
Function Select: Utility: System: Operation Mode
144
Function Select: Utility: System: Year Display
144
Function Select: Utility: System: Test Mode Status
144
Function Select: Utility: System: Lamp Test
145
Function Select: Utility: System: Self Test
145
Function Select: Utility: System: Display Contrast
145
Function Select: Utility: System: M&C Firmware
146
Function Select: Utility: System: Boot Firmware
146
Function Select: Utility: System: Fpga Firmware
147
Function Select: Utility: System: Demo Mode
147
Ext Agc: Max Pwr
147
Ext Agc: Min Pwr
148
Function Select: Utility: System: Master Reset
148
Modem Type
149
Card #2 Type
151
Card #3 Type
151
Card #1 Options
152
Card #2 Options
152
Card #3 Options
153
Local Modem Aupc
153
Modem Serial
154
Card #1 Serial
154
Card #2 Serial
154
Card #3 Serial
155
Function Select: Utility: Factory Set-Up
158
Custom Modem Defaults
159
Table 4-2. Custom Modem Defaults
159
Chapter 5. Modem Type
163
Modem Type
163
Table 5-1. Modem Type Selection
163
AUPC Operation (with Reed-Solomon)
164
Closed Network Operation (Comtech EF Data)
164
Custom Operation
165
Table 5-2. Comtech Efd Closed Network Parameter Settings
165
Reed-Solomon Modes
166
Table 5-3. Reed-Solomon Modes
166
Clocking Options
167
EIA-232, EIA-422, or V.35 Master/Master
167
EIA-232, EIA-422, or V.35 Master/Slave
167
CHAPTER 6 Buffering
168
Buffer Size
168
Figure 6-1. Eia-422, Eia-232, or V.35 Master/Master Clocking Diagram
169
Figure 6-2. Eia-422, Eia-232, or V.35 Master/Slave Clocking Diagram
170
Figure 6-4. Doppler Shift
172
Doppler
173
Plesiochronous
174
Frame/Multiframe Length
175
Multiples of the Frame Length
175
Total Buffer Length
175
Converting between Bits and Seconds
175
Introduction
177
Coding
178
Turbo Product Codec (Hardware Option)
178
Introduction
178
Table 7-1. Available Tpc Modes
178
Mod/Demod Processing Delay
179
Comparison of All TPC Modes
179
Table 7-2. Turbo Product Coding Processing Delay Comparison
179
Uncoded Operation (no FEC)
180
Figure 7-1. Viterbi Decoder
183
Figure 7-2. Viterbi Decoder and Reed-Solomon
184
Figure 7-3. Bpsk and {O}Qpsk Ber Performance
185
Figure 7-4. Turbo Product Codec
186
Figure 7-5. Sequential Decoder, Reed-Solomon, and 1544 Kbps
187
Figure 7-6. Sequential Decoder and 56 Kbps
188
Figure 7-7. Sequential Decoder and 1544 Kbps
189
Chapter 8. System Checkout
191
System Checkout
191
8.1.1 Interface Checkout
192
Figure 8-1. Fault Isolation Test Setup
192
Modulator Checkout
193
Table 8-1. Conversion to S/N and Eb/N0 Chart
194
Demodulator Checkout
195
Figure 8-2. Typical Output Spectrum
195
Figure 8-3. Typical Eye Constellations
196
Chapter 9. Fault Isolation
197
Fault Isolation
197
System Faults/Alarms
198
Faults/Alarms Display
198
Faults/Alarms Analysis
198
Modulator Faults
201
Demodulator Faults
202
Common Equipment Faults
203
Chapter 10. Automatic Uplink Power Control
205
Aupc
205
Figure 10-1. Aupc Block Diagram
206
Modes of AUPC Location
207
Table 10-1. Setting Aupc Parameters
207
AUPC - between Two Modems
208
Self-Monitoring Local Modem AUPC Control
209
Remote Aupc
209
MUX Operation
210
DEMUX Operation
210
Buffer Operation
210
Loop Timing Operation
211
Baseband Loopback Operation
211
Front Panel Operation
211
Aupc Modem Defaults
212
Chapter 11. Asymmetrical Loop Timing
213
Asymmetrical Loop Timing
213
Figure 11-1. Transmit Section of the Asymmetrical Loop Timing Block Diagram
214
Figure 11-2. Receive Section of the Asymmetrical Loop Timing Block Diagram
215
Chapter 12. Fully Accesible System Topology (Fast)
217
FAST System Theory
217
Implementation
217
Activation Procedure
218
Variable Data Rates
221
Chapter 13. Buc Fsk Communications
223
Introduction
223
Transmission Interface
224
Message Structure
224
Command Message Structure (IDU to ODU)
224
Response Message Structure (BUC to IDU)
225
Power Class
225
Chapter 14. Decoder
227
Decoder
227
Sequential Decoder
227
Figure 14-1. Sequential Decoder Block Diagram
227
Viterbi Decoder
229
Figure 14-2. Viterbi Decoder Block Diagram
229
Chapter 15. Reed-Solomon Codec
233
Reed-Solomon Codec
233
Figure 15-1. Reed-Solomon Pcb (As/5304-1)
233
Specifications
234
Theory of Operation
234
Figure 15-2.Reed-Solomon Codec Block Diagram
234
Reed-Solomon Encoder
235
Figure 15-3. Reed-Solomon Encoder Section Block Diagram
235
Figure 15-4. Reed-Solomon Code Page Format
236
Reed-Solomon Decoder
237
Figure 15-5. Reed-Solomon Decoder Section Block Diagram
237
Appendix Aspecification
239
Specifications
239
Specification Summary
240
Table A-1. System Specification Summary
240
L-Band Modulator Specification Summary
241
Table A-2. L-Band Modulator
241
Demodulator Specification Summary
242
Table A-3. Demodulator Specification
242
L-Band Modulator Specifications
243
Digital Data Rate
243
Table A-4. Modulator Digital Data Rates
243
Modulation and Encoding Types
244
Table A-5. Modulation and Encoding Types
244
Scrambling Types
245
Modulator Frequency Reference
245
Table A-6. Scrambling Types
245
Modulator Spurious Emissions
246
Modulator Phase Noise
246
Modulator if Output Spectrum Shape
246
L-Band INMARSAT Spurious Emissions
246
Differential Encoder
247
BPSK Bit Ordering
247
Interleaver (Reed-Solomon Codec
247
Modulator Transmit Frequency (if
247
Transmit Frequency Change Time
247
Modulator Transmit if Output Switch
247
Modulator Transmit if Power
247
Modulator Power Offset
248
Modulator I / Q Imbalance
248
Modulator Output Noise Floor
248
Modulator Spectrum Rotation
248
Modulator Output Return Loss
248
L-Band ODU Reference Signal
248
L-Band ODU Control and Monitor
248
Modulator Transmit if Test Modes
248
L-Band ODU Supply Voltage
249
ODU DC Current Sense
249
Encoding
249
BPSK Encoding
249
OQPSK Encoding
250
8-PSK Encoding
250
L-Band Demodulator Specifications
251
Digital Data Rate
251
Table A-7. Demodulator Digital Data Rate
251
Demodulation and FEC Decoding Types
252
Table A-8. L-Band Demodulation and Fec Decoding Types
252
Descrambling Types
253
Differential Decoder
253
BPSK Bit Ordering
253
Deinterleaver (Reed-Solomon Codec
253
Demodulator Spectrum Rotation
253
Table A-9. Descrambling Types
253
Receive Frequency
254
Input Overload
254
Demodulator Input Return Loss
254
LNB Prime Power
254
LNB Band Control
254
LNB Reference Signal
254
Receive Input Power (Composite
255
Demodulator Input Shape
255
Receive Input Power (Desired Carrier
256
Demodulator Channel Spacing/Adjacent Carrier Performance
256
Figure A-1. Carrier Level Vs Symbol Rate
256
Bit Error Rate Performance
257
Performance with Noise, Viterbi Decoder, and Closed Network
257
Performance with Noise, Viterbi Decoder, and Reed-Solomon (Optional
257
Performance with BPSK and {O}QPSK BER Performance
257
Performance with Noise Turbo Product Codec (Optional
258
Performance with Noise, 1544 Kbps Sequential Decoder and Reed Solomon(Optional
258
Performance with Noise, 56 Kbps Sequential Decoder (Optional
258
Performance with Noise, 1544 Kbps Sequential Decoder (Optional
259
BER Threshold
259
Acquisition Time
260
Receive Carrier Acquisition Range
261
Receive Carrier Reacquisition
261
AGC Output
261
Doppler Tracking Performance
261
Interface Specifications
262
TX Clock Switching Due to Failure of Selected Clock
262
TX Clock Phase Adjustment
262
TX Data Phase Adjustment
262
Transmit Clock Source
262
Send Clock Timing Source
262
Doppler/Plesiochronous Buffer Clock Source
263
RX Clock Switching Due to Failure of Selected Clock
263
RX Clock Phase Adjustment
263
RX Clock Jitter
263
RX Data Phase Adjustment
263
Buffer Centering
263
Receive Doppler/Plesiochronous Buffer Size
264
Switch Faults
264
Decoding
264
BPSK Decoding
264
QPSK Decoding
264
Offset QPSK Decoding (Optional
265
8-PSK Decoding
265
Terrestrial Interface Types
266
EIA-232 Specification
266
V.35 Specification V.10, V.11 Specification, Circuit Supported
267
EIA-449/EIA-422 Mil-188-114A Specification
268
AUPC Specification (Optional
269
AUPC Parameters
270
AUPC with Reed-Solomon Option
270
Turbo AUPC
270
Table A-10. Aupc Parameters
270
System Specifications
271
Loopback Modes
271
Test Modes
271
Remote Control
272
Modem Remote Address
272
Monitored Signals
272
Stored Faults
273
Stored Configurations
273
Interoperability Modes
273
Appendix B. Remote Control Operation
275
General
275
Message Structure
276
Start Character
276
Device Address
276
Command/Response
277
End Character
278
Configuration Commands/Responses
279
Modulator Configuration Commands
279
B.3.2 Demodulator Configuration Commands
281
B.3.3 Interface Configuration Commands
283
B.3.4 System Configuration Commands
285
Automatic Uplink Power Control (AUPC
286
B.4 Status Commands/Responses
288
B.4.1 Modulator Configuration Status
288
ODU Configuration Status
293
Fault Status
294
B.4.2 Error Performance
295
Stored Faults
298
Appendix C. Burst Mode Modulator Operation
315
Burst Mode Modulator: Theory of Operation
315
Burst Mode
315
Burst Mode Modulator: Specifications
316
Digital Data Rate
316
Modulation and Encoding Types
316
Scrambling Types
317
Differential Encoder
317
Transmit Frequency (if
317
Frequency Reference
317
Transmit Frequency Change Time
317
Phase Noise
318
Transmit if Output Switch
318
Transmit if Power
318
Modulator Power Offset
318
Modulated if Output Shape
318
Spurious Emissions
319
Modulator Phase Error
319
Transmit if Test Modes
319
Modulator Spectrum Rotation
319
Transmit Preamble
320
Transmit Packet
320
Transmit Postamble
320
Burst Mode Demodulator: Theory of Operation
321
Burst Mode
321
Burst Mode Demodulator: Specifications
322
Digital Data Rate
322
Demodulation and FEC Decoding Types
322
Descrambling Types
322
Differential Decoder
323
Demodulator Spectrum Rotation
323
Receive Frequency (if
323
Receive Input Power (Desired Carrier
323
Receive Input Power (Composite
323
IF Input Overload
323
Demodulator if Input Shape
323
Channel Spacing/Adjacent Carrier Performance
324
Acquisition Time
324
Acquisition Probability
324
Receive if Carrier Acquisition Range
324
Collision Recovery
325
Burst Mode System - Specifications
325
Loopback Modes
325
Remote Control
326
Modem Remote Address
326
Monitored Signals
326
Faults Monitored
326
Figure C-1. Snm-1001L Burst Mode Fault Tree
327
Stored Faults
330
Stored Configurations
330
Burst Mode Specifications
331
Glossary
333
Index
337
Demodulator Faults
338
Advertisement
Advertisement
Related Products
Comtech EF Data SLM-5650
Comtech EF Data SDM-100A
Comtech EF Data SDM-300L3
Comtech EF Data SDM-309B
Comtech EF Data SDM-650B
Comtech EF Data SLM-7650
Comtech EF Data SDM-9000
Comtech EF Data SDM-300A
Comtech EF Data SMS-301
Comtech EF Data SLM-5650C CyberLynx
Comtech EF Data Categories
Modem
Switch
Amplifier
Network Router
Media Converter
More Comtech EF Data Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL