DIS(P)
Operation Error
(1) In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and
an error code is stored into SD0.
• The range n-points from
• The value of n is outside the 0 to 4 range.
Program Example
(1) The following program dissociates the 16-bit data from D0 into 4-bit groups, and stores from
D10 to D13 when X0 is ON.
[Ladder Mode]
[Operation]
b15
D0
1 1 0 0 1 0 0 1 0 1 0 1 0 0 0 1
7-78
exceeds the relevant device.
D
b12 b11
b8
b7
b4 b3
b0
[List Mode]
Step
Instruction
b15
b4
b3
b2
D10
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1
D11
0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1
D12
0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 1
D13
0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0
Filled with 0s.
Storage area
(Error code: 4101)
(Error code: 4100)
Device
b1
b0