6.4.3
Floating-point data transfer (Double precision) (EDMOV(P))
EDMOV(P)
EDMOV
EDMOVP
Setting
Data
S
D
Function
Transfers 64-bit floating decimal point type real number data being stored at the device
designated by
S
64-bit floating-point real number
Operation Error
(1) There are no operation errors associated with the EDMOV(P) instruction.
Command
Command
: Data to be transferred or number of the device to which the data to be transferred is stored (real number)
S
: The number of the device to which the transferred data will be stored (real number)
D
Internal Devices
R, ZR
Bit
Word
––
––
to a device designated by
S
+3
S
+2
S
+1
S
Transfer
4.23542
High
Basic
performance
EDMOV
EDMOVP
J
\
U
\G
Bit
Word
––
––
.
S D
D
+3
D
+2
D
+1
D
4.23542
64-bit floating-point real number
EDMOV(P)
Process
Redundant
Universal
LCPU
S
D
S
D
Constants
Zn
Other
E
––
––
––