Mitsubishi MELSEC Q Series Programming Manual page 980

Common instruction 1/2
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Error
Code
Error Contents and Cause
(SD0)
[OPERATION ERROR]
The instruction cannot process the contained data.
■Collateral information
• Common information: Program error location
• Individual information:-
■Diagnostic Timing
• When instruction executed
[OPERATION ERROR]
An error occurred on the SP.FREAD or
SP.FWRITE instruction during accessing the ATA
or SD memory card.
■Collateral information
4100
• Common information: Program error location
• Individual information:-
■Diagnostic Timing
• When instruction executed
[OPERATION ERROR]
The file being accessed by other functions with
SP.FWRITE instruction was accessed.
■Collateral information
• Common information: Program error location
• Individual information:-
■Diagnostic Timing
• When instruction executed
[OPERATION ERROR]
• The number of setting data dealt with the
instruction exceeds the applicable range.
• The storage data and constant of the device
specified by the instruction exceeds the
applicable range.
• When writing to the host CPU shared memory,
the write prohibited area is specified for the write
destination address.
• The range of storage data of the device
specified by the instruction is duplicated.
• The device specified by the instruction exceeds
the range of the number of device points.
• The interrupt pointer No. specified by the
instruction exceeds the applicable range.
• A link direct device, intelligent function module
4101
device, and cyclic transmission area device are
specified for both (S) and (D) with the BMOV
instruction.
■Collateral information
• Common information: Program error location
• Individual information:-
■Diagnostic Timing
• When instruction executed
[OPERATION ERROR]
• The storage data of file register specified by the
instruction exceeds the applicable range. Or, file
register is not set.
■Collateral information
• Common information: Program error location
• Individual information:-
■Diagnostic Timing
• When instruction executed
12-60
Corrective Action
Read common information of the error using the
programming tool to identify the numeric value
(program error location). Check the error step
corresponding to the value, and correct it as
necessary.
• Take measurements against noise.
• Reset and restart the CPU module. If the same
error code is displayed again, the cause is a
hardware failure of the ATA card or SD memory
card. (Please consult your local Mitsubishi
representative, explaining a detailed
description of the problem.)
• Stop the file accessed with other functions to
execute SP.FWRITE instruction.
• Stop the access with other functions and the
SP.FWRITE instruction to execute at same
time.
Read common information of the error using the
programming tool to identify the numeric value
(program error location). Check the error step
corresponding to the value, and correct it as
necessary.
LED Status
Corresponding
CPU Status
CPU
QCPU
LCPU
Qn(H)
QnPH
QnPRH
*19
QnU
LCPU
*19
QnU
LCPU
RUN:
Off/On
ERR.:
Flicker/On
CPU Status:
Stop/
*1
Continue
QCPU
LCPU
*18
QnU
LCPU

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec l series

Table of Contents