Mitsubishi MELSEC Q Series Programming Manual page 128

Common instruction 1/2
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Instruction Symbols
+,-,+P,-P,D+,D-,D+P,D-P,
WAND,WOR,WXOR,WXNR,
DAND,DOR,DXOR,DXNR,
WANDP,WORP,WXORP,WXNRP,
DANDP,DORP,DXORP,DXNRP
1
(3 devices)*
Instruction Symbols
*
, *P, /, /P
D*, D*P, D/, D/P, E*, E*P
MOV,MOVP,DMOV,DMOVP,EMOV,EMOVP
BCD,BCDP,BIN,BINP,DBCD,DBCDP,
DBIN,DBINP,FLT,FLTP,DFLT,DFLTP,
INT,INTP,DINT,DINTP,CML,CMLP,
DCML,DCMLP
Devices with Additional Steps
Intelligent function module device
Multiple CPU shared device
Link direct device
Index register / standard device register
Serial number access format file register
Extended data register(D)
Extended link register(W)
32-bit constant
Real constant
Character string constant
(d) In cases where the conditions described in (a) to (c) above overlap, the number of steps
3-38
*1:
If the same device is used for
2) Except Instructions applicable to subset processing
The following table shows steps depending on the devices.
becomes a culmination of the two.
Locations Where Standard Device Regis-
ter Is Used
,
, and
D
S1
S2
,
or
and
S1
S2
and
S1
S2
(only when that device that the
number of steps does not increase is
specified for
D
and
S1
S2
(only when a serial number access format
file register is specified for
and
, the number of basic steps increases by one.
D
S1
Locations Where Standard Device Regis-
ter Is Used
,
, and
D
S1
S2
, or
and
S1
S2
,
, and
D
S1
S2
, or
and
S1
S2
and
S1
S2
(only when that device that the
number of steps does not increase is
specified for
D
and
S1
S2
(only when a serial number access format
file register is specified for
and
D
S1
and
D
S1
Added Steps
1
For even number: (number of characters) / 2
For odd numbers: (number of characters + 1) / 2
Added Steps
(Number of
Instruction Steps)
-2(1)
-1(2)
D
±
0(3)
)
+2(5)
)
D
Added Steps
(Number of
Instruction Steps)
-2(1)
-1(2)
D
-2(1)
-1(2)
D
±
0(3)
)
+2(5)
)
D
-1(1)
-1(1)
MOV U3E1\G10000 D0
Basic Number of
Steps
3
Basic Number of
Steps
3
3
2
2
Example
MOV U4\G10 D0
MOV J3\B20 D0
MOV Z0 D0
MOV ZR123 D0
MOV D123
MOV W123
DMOV K123 D0
EMOV E0.1 D0
$MOV "123" D0