Configuring Ipwatchd; Figure 56. Vrrp-Operation Window; Figure 57. Vrrp-Circuit Failover Window (1); Figure 58. Vrrp-Circuit Failover Window (2) - Samsung WEC8500 Operation Manual

Access point controller
Hide thumbs Also See for WEC8500:
Table of Contents

Advertisement

Figure 56.
VRRP-Operation Window
[Circuit Failover]
When you click the Circuit Failover menu, the VRRP list is displayed on the window.
Figure 57.
VRRP-Circuit Failover Window (1)
To perform a detailed configuration, select one of VRRP items.
After selecting a configuration you want select the <Apply> button to apply the
configuration.
Figure 58.
VRRP-Circuit Failover Window (2)

Configuring IPWATCHD

The IP WATCH Daemon (IPWATCHD) provides the function of detecting active or
passive IP collision. Regardless of IP collision attacker or victim, the information including
source ip/mac is transmitted as an evm fault event when the IP collision occurs. At the
collision time, the Gratuitous Address Resolution Protocol (GARP) reply is transmitted 3
times to the unicast at every 1 second.
It supports the rate-limit function to deal with an intended ARP attack. Although ARP is
entered from a host that is not in the same subnet, it generates GARP by recognizing it as
a target if the host has the same APC IP.
Configuration using CLI
To configure the IPWATCHD function, enter into the configure mode of CLI.
Configure a TIMEOUT value (that a user wants) to detect an IP address collision.
WEC8500/WEC8050 (APC) Operation Manual v10.1