Configuration using Web UI
In the menu bar of <WEC Main window>, select <Configuration> and then select the
<AP Groups> menu in the sub-menus.
After selecting the name of the remote AP group, you can configure DHCP in the
"INTERFACE" item of the 'Remote AP Group' tab.
Figure 114.
Remote AP Group Configuration Window
Configure Mesh AP Group
Mesh AP group supports to manage APs connected together without a wired connection.
Apart from Root-Repeater service, Mesh service supports multi-hop function. It also
provides a monitoring function.
Exceptionally, Station Service, Wired Bridge and Monitoring function can be configured
individually. In the Mesh AP group, the operator can configure the below information and
the APs in the Mesh AP group which operates based on the same configuration.
•
•
•
•
•
WEC8500/WEC8050 (APC) Operation Manual v10.1
©Samsung Electronics America
Max Node
o Configure Max number of Mesh AP connected with Root AP.
Max Hop
o Configure Max number of hop from Root AP.
Automatic Access Allowed
o Configure Mesh AP to allow wireless connect without mesh
configuration.
Station Service
o Configure using WLAN service by backhaul band.
Wired Bridge
o Configure Mesh AP to the providing bridge service using wired port
167