Configuration using Web UI
In the menu bar of <WEC Main window>, select <Configuration> and then select the
<AP Groups> menu in the sub-menus. After selecting the name of a Mesh AP group, you
can configure additional functons in item of the 'Mesh' tab.

AP Time Synchronization per Group

The AP can configure its time information using either the time stamp method or the NTP
method.
In the Time Stamp type, the APC periodically transmits the time of APC to an AP and the
AP is operating with the received time. Unless a user changes the configuration, the default
is Time Stamp type and the interval is set to 7200 seconds (2 hours).
In the NTP type, the NTP server information is transmitted to an AP and the AP
synchronizes the time with the NTP server. A NTP server list must be created to transmit
the NTP server information to an AP and maximum 10 lists can be added. The ntp-interval
(2^N) is the interval when an AP receives the time information from the NTP server.
For example, if the ntp-interval is set to 6, an AP receives the time information from the
NTP server at every 2^6, that is 128 seconds.
The APC provides a function for configuring the time configuration method of the AP.
Configuring Time Stamp Type using CLI
1
WEC8500# configure terminal
WEC8500/configure# apc
WEC8500/configure/apc# ap-time-config
WEC8500/configure/apc/ap-time-config#
2
WEC8500/WEC8050 (APC) Operation Manual v10.1
©Samsung Electronics America
Go to configure  apc  ap-time-config configuration mode of CLI.
Configure how to transmit the time information to an AP using 'ac-stamp'
and configure the interval.
o mode ac-stamp
171