Chapter 6: Electrical Specifications; 9006Ac Specifications - Avaya Virtual Services Platform 9010 Manual

Installing ac power supplies
Hide thumbs Also See for Virtual Services Platform 9010:
Table of Contents

Advertisement

Chapter 6: Electrical specifications

This chapter lists the electrical specifications and provides power ratings for the AC power supplies.

9006AC specifications

This section provides the input and output power specifications for the 9006AC power supply.
AC input power specifications
The following table describes the technical specifications for AC input power for the 9006AC power
supply.
Table 5: Input power specifications
Parameter
Input current
Operating frequency range
Input volt-ampere (VA)
Efficiency
Input power consumption
Heat dissipation (thermal output)
Hold-up time (See note 1.)
Note 1: Measurement starts at zero crossing of the AC voltage. Measurement made at full load and voltage
is allowed to decay to 44 VDC.
DC output power specifications
The following table describes the technical specifications for the DC output power for the 9006AC
power supply.
Installing AC Power Supplies in Avaya VSP 9000
26
Specification at input voltage
90-140 VAC
13.3 A (100 VAC) - 11.2 A (120
VAC)
47–63 Hz
1445 VA
85% minimum, 90% typical
1,416 W
724 British Thermal Unit (BTU)/
hour
25 ms
Comments? infodev@avaya.com
Specification at input voltage
185-275 VAC
11.8 A (200 VAC) – 9.9 A (240
VAC)
47–63 Hz
2325 VA
88% minimum, 93% typical
2,277 W
933 BTU/hour
20 ms
December 2014