External Alarm Cabling Specifications - Avaya S6200 Manual

Conferencing servers, meeting exchange 4.1
Hide thumbs Also See for S6200:
Table of Contents

Advertisement

Installing S6x00 Hardware

External Alarm Cabling Specifications

The external alarm relay contacts on the media server have the following characteristics:
Normally open contacts for critical, major, and minor alarms
Contact current is 2 A maximum•Contact resistance is protected by 0.165 mF/477 W
The external relay contacts have the following dielectric strengths:
1500 VAC (50/60 Hz for 1-min) between the coil and the contacts
1000 VAC (50/60 Hz for 1-min) between the contacts of the same pole•1000 VAC (50/60
Hz for 1-min) between the contacts of different poles
The external relay contacts can withstand the following surges:
2500 V, 2x10 msec between the coil and the contacts, in compliance with Bellcore
standards
1500 V, 10x160 msec between the contacts of the same pole, in compliance with FCC Part
68
Pin
Description
1
No connection
2
External Alarm 2
3
No connection
4
No connection
5
No connection
6
Critical Audible 1
7
Critical Visual 1
8
Minor Audible 1
9
Major Audible 1
10
No connection
11
Minor Visual 1
12
Major Visual 1
13
No connection
14
No connection
15
External Alarm 1
40 Installing the S6200, S6500, and S6800 Conferencing Server
Function
Input
Dry Contact Out
Dry Contact Out
Dry Contact Out
Dry Contact Out
Dry Contact Out
Dry Contact Out
Input
Connected to:
Alarm State
External Alarm High
Critical Audible 2
Critical Visual 2
Minor Audible 2
Major Audible 2
Minor Visual 2
Major Visual 2
External Alarm High
Power Fail State
Same
Same
Open
Open
Open
Open