Table E-4. DS1 and E1 Input Module Default Configuration (Continued)
Configuration Setting
MTIE Limits
MTIE Limit 1 Alarm Mode
MTIE Limit 2 Alarm Mode
Alarm Initial Severity
Alarm Initial Delay
Alarm Elevation Time
Port Status
Port Name
MTIE Limits for the DS1 Input Module
Table E-5
provides MTIE limits for the DS1 Input Module configuration and factory
defaults and settings.
Table E-5. DS1 Input Module – MTIE Limits
Time
Set Limit L1
(seconds)
10
260
100
440
1000
810
10000
880
100000
1600
12713020-002-2 Revision D – April 2004
Factory Default
See
Table E-5
MINOR
MAJOR
MINOR (except LOS and Level 2
MTIE, which are MAJOR)
0 seconds
86,400 seconds
Disabled
Not applicable
Set Limit L2
(ns)
(ns)
325
550
1010
1100
2000
DS1 and E1 Input Module Default Settings
and
Table E-6
Clear Limit L1
(ns)
230
400
730
790
1440
Range
1 to 10,000
Ignore, Report, Minor, Major,
or Critical
Ignore, Report, Minor, Major,
or Critical
Ignore, Report, Minor, Major,
or Critical
0 to 86,400 seconds
0 to 500,000 seconds
Enabled/Disabled
Any user selected string from
0 to 20 characters
Clear Limit L2
(ns)
290
490
910
990
1800
SSU-2000 User's Guide 425