Symmetricom SSU-2000 User Manual page 306

Synchronization supply unit and the synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

TL1 Command Interface
Table B-6. TL1 Set Commands (Continued)
Command
SET-PRMTR-ALARM:[tid]:aid:
ctag::almnum,level
[,errcnt],[clrcnt];
SET-PRMTR-AIS:tid:[aid]:ctag
::[errcnt],[clrcnt];
SET-PRMTR-BPV:tid:[aid]:ctag
::[errcnt],[clrcnt];
SET-PRMTR-CRC:tid:[aid]:ctag
::[errcnt],[clrcnt];
SET-PRMTR-LOS:tid:[aid]:ctag
::[errcnt],[clrcnt];
SET-PRMTR-OOF:tid:[aid]:ctag
::[errcnt],[clrcnt];
SET-PRMTR-CCOUT:[tid]:[aid]:
ctag::[pstate],[mode],
[level],[bypass],[duty],
[pcomp];
SET-PRMTR-CLK:[tid]:[aid]:
ctag::[warmup],[mintau],
[maxtau];
306 SSU-2000 User's Guide
Valid aid code:
,
ALL
SxAy
This command assigns an alarm level to the alarm number
specified.
= alarm number. See
almnum
242 for a list of alarm numbers.
= [IGN|RPT|MIN|MAJ|CRT]
level
start delay time or erred seconds count
and clear delay time for the indicated alarm
errcnt
number
on the modules specified by the aid.
clrcnt
Valid aid code:
,
ALL
SxAy-[z]
This command sets the input error and clear parameters of
[AIS|BPV|CRC|LOS|OOF] for the designated input.
and
errcnt
clrcnt
[0|...|100] before reporting the condition for LOS and AIS
input errors
and
errcnt
clrcnt
[0|...|100000] before reporting the condition for OOF, BPV,
and CRC input errors
When aid is set to ALL, the specified parameters are set for
all inputs.
Valid aid code:
,
ALL
SxA[y[-z]]
sets the output port [ON|OFF]
pstate
= ignored
mode
= the condition where outputs are turned on
level
[WARM |ACQ|LOCK]
= allow Clock C selection: [ON|OFF]
bypass
= set duty cycle to use 5/8 or 50/50 [1|0]
duty
= set phase compensation delay to [0 through 8],
pcomp
where 0 = No compensation and 8 = 4000 ft. The
resolution of pcomp values is 500 ft. Setting the status for
a module (no port
–z
[ON|OFF]
Empty fields leave parameters unchanged.
Valid aid code:
,
S1A1
S1A12
This command sets the designated clock warmup time.
= warmup time constant; set to 1200 seconds
warmup
= starting time constant
mintau
= final time constant value
maxtau
ST2E tau range = [300–10000]
ST3E tau range = [150–1200]
The aid may be specified to indicate which clock; set to null to
set both clocks identically.
Empty fields leave parameters unchanged.
Description
Alarm
Messages, on page
= number of seconds to delay
= number of seconds to delay
) sets all ports on the module to
,
,
CLK-A
CLK-B
12713020-002-2 Revision D – April 2004