Hardware Configuration Guide
Configuring a Subtending SSU
Changing to Subtending SSU Mode
To change an SSU-2000 to a Subtending SSU, you must verify that the proper
hardware is present, and you must install the appropriate software. The minimum
software versions for the modules is listed in
Table 9-1. Minimum Software Versions for Subtending Operation
Communications:
Basic Load
Basic + NTP
Basic + SNMP
Basic + NTP + SNMP
Clock (ST2 or ST3E)
Composite Clock Input
Composite Clock Output
Required Hardware
The Subtending SSU mode requires the following modules in the shelf:
CC Input module
CC Output module
All other available modules can be used in the Subtending SSU mode. The shelf
must contain the appropriate Clock module(s), Communications module, and Input
and Output modules.
230 SSU-2000 User's Guide
Module
Table
9-1.
Minimum Revision Level
D.00
B.00
B.00
B.00
C.00
A.00
PLD: B.00
S/W: B.00
12713020-002-2 Revision D – April 2004