Symmetricom SSU-2000 User Manual page 298

Synchronization supply unit and the synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

TL1 Command Interface
Table B-5. TL1 Retrieve Commands (Continued)
Command
RTRV-PRMTR-OUTPUT:[tid]:[aid]
:ctag;
298 SSU-2000 User's Guide
Valid aid code:
,
ALL
SxA[y[-z]]
Returns the output port setting when a port aid is specified.
The format for the response message is:
^^^"aid:mode,level,bypass,zs,crc,bit,pstate,len"
<cr lf>
where:
= aid of the port
aid
= output signal mode [ESF|D4|CCS|CAS]
mode
= [WARM|ACQ|LOCK] for the clock level where
level
outputs are turned on
= allow Clock C selection [ON|OFF]
bypass
= zero suppression
zs
= error checking crc are [ON|OFF]
crc
= SSM bit [4 through 8] for E1 sync status messages
bit
= port enabled state [ON|OFF]
pstate
= line length setting of [133|266|399|533|655] for
len
DS1 outputs
When the aid does not specify a port, the response is:
^^^"aid:mode,level,bypass,zs,crc,bit" <cr lf>
^^^"aid:pstate1,pstate2,...pstate20" <cr lf>
^^^"aid:len1,len2,len3,...,len20" <cr lf>
Line 1 contains:
= module access identifier
aid
= outputs signal mode: [ESF|D4|CCS|CAS]
mode
= clock level: [WARM|ACQ|LOCK] when outputs
level
are turned on
= allow Clock C selection: [ON|OFF]
bypass
= zero suppression: [ON|OFF]
zs
= error checking: [ON|OFF]
crc
= SSM bit [4 through 8] for E1 sync status messages
bit
Line 2 contains:
= port access identifier
aid
= port enabled state [1|0] (1 = ON and 0 = OFF)
pstate#
and
is the port number 1 through 20
#
Line 3 contains:
= access identifier of the port
aid
= line length setting of [133|266|399|533|655] for all
len#
20 DS1 output ports and
20
Description
is the port number 1 through
#
12713020-002-2 Revision D – April 2004

Advertisement

Table of Contents
loading

Related Products for Symmetricom SSU-2000

This manual is also suitable for:

Sdu-2000

Table of Contents