Symmetricom SSU-2000 User Manual page 305

Synchronization supply unit and the synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Table B-6. TL1 Set Commands (Continued)
Command
SET-GPS-POS:[tid]:[aid]:
ctag::[(lat)],[(lon)],
[(hgt)],[pdop],[avg],
[posel],[timel];
SET-INPUT-REF:[tid]::ctag::
port[,swtmode] [,selmode];
SET-MTIE-MASK:[tid]:[aid]:
ctag::mask;
SET-NAME:[tid]:[aid]:ctag::
name;
SET-PHASE-ZERO:[tid]:[aid]:
ctag[::clksrc];
12713020-002-2 Revision D – April 2004
Valid aid code:
or
S1A3
This command sets the position mask for the GPS module
designated by the aid.
The settings for this command include:
= set the latitude [
lat
(DD)-MM-SS.SS, where + = North and – = South
= set longitude [
lon
(DD)-MM-SS.SS, where + = East, and – = West
±
= set height [
hgt
= set the pdop [1 to 10]
pdop
= set position averaging value [10 to 3600]
avg
= set the minimum satellite elevation to use for
posel
positioning [0 to 50 deg]
= set the minimum satellite elevation to use for
timel
timing [0 to 50 deg]
Valid aid code: None
This command sets the current input reference to the
designated input port.
= [AR|AS|OFF] for autoreturn (revertive)
swtmode
selection, autoswitch (non-revertive), or no auto switching
= reference selection: [PRI|PQL] for priority or
selmode
status message selection of inputs
If the input port is not a valid reference, then the DENY
response is returned.
Valid aid code:
,
ALL
SxAy-[z]
This command will set the MTIE mask for the given input to
predefined settings, such that mask can be set to PRS| DS1|
G811|G823. The MTIE mask settings include both Limit 1 and
Limit 2 and set and clear thresholds. For user defined
thresholds, use the SET-PRMTR-MTIE command.
Valid aid code: none,
S1A2
This command with no aid or S1A2 (Communications
Module) assigns a new name to the unit. The tid (if used)
must match the original name, which is returned in the
response sid. The new unit name must be used as the tid
(and sid) for all commands following.
For an aid designating an Input or Output port the name is
assigned to the port. The name for unit or port may be null or
as many as 20 characters beginning with a letter.
Valid aid code: none or Input port aid.
This command sets the input phase to zero for the designated
port(s) or all input ports with an aid of null or ALL. If clksrc is
specified [CLK-A|CLK-B] only the one phase value is set to
zero; otherwise both values are set to zero.
TL1 Command Interface
Description
(must be a GPS module)
S1A5
±
90deg], formatted
±
180 deg] formatted as
10000.0 meters]
, or I/O port
.
aid
SSU-2000 User's Guide 305