Symmetricom SSU-2000 User Manual page 336

Synchronization supply unit and the synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Interactive Command Set
Remarks
Related
Restrictions None
The following is an example of the
SSU_2000->ENGINE
2001-06-18T20:46:20Z ID: SSU2000 Name: SSU_2000
GPS Module: 1A03
GPS MOT Engine: 2.2, APR 24 1998
Lat: +30:27:15.89, Lon: -097:39:45.88, Ht: 230.81 m (3D)
PDOP: 2.7, 300 ave
GPS Module: 1A05
GPS MOT Engine: 2.2, APR 24 1998
Lat: +30:27:15.75, Lon: -097:39:45.85, Ht: 233.43 m (3D)
PDOP: 2.8, 10 ave
336 SSU-2000 User's Guide
ELMASK Default values for the masks are 5 degrees for the
positioning mask and 10 degrees for time.
POS
Only set the position if you know the accurate position.
The software automatically verifies the position on
restart. The unit averages 10 position fixes and
compares them to the fixed position.
If the position is within 100m RMS, no position updates
are performed. If the position error is > 100m RMS, an
event is generated stating that the position is being
recalculated, and the position is recalculated and
updated in the NVRAM. Similarly, setting the AVG time
puts the unit back into survey mode, which generates
an event that the position is being recalculated.
TDATA
Engine reports are asynchronous outputs, which means
they can occur at any time, not necessarily at the time
the command is issued.
None
command message format:
ENGINE
12713020-002-2 Revision D – April 2004

Advertisement

Table of Contents
loading

Related Products for Symmetricom SSU-2000

This manual is also suitable for:

Sdu-2000