TL1 Command Interface
Table B-5. TL1 Retrieve Commands (Continued)
Command
RTRV-DATA-PHASE:[tid]:aid:
ctag[::tmper[,clksrc[,start]
[,stop]]];
282 SSU-2000 User's Guide
Valid aid code:
S1Ay-z
Returns phase data from phase history buffers. The
command requires an aid to identify the input to report data
from.
is followed by a null field
ctag
= optional parameter containing the averaging
tmper
time period for data to be returned: [100|1000|10000] with
the default of 100 if not specified
= [CLK-A|CLK-B] or both (on separate message
clksrc
lines) if not specified
The format for each response message line is:
^^^"aid:ocrdat,ocrtm,PHA,clksrc,tmper,(monval)"
<cr lf>
where:
and
are the actual date and time the data
ocrdat
ocrtm
was collected
is [CLK-A|CLK-B] indicating the clock used for
clksrc
the measurements
= time period of the measurement data, given as
tmper
xSEC where x = time in seconds
= +/- phase values versus clock for the specified
monval
input given in nanoseconds enclosed in parentheses
= start time specifies the start date and time for
start
data in the format MM-DD,HH-MM. If the date is null but
followed by a time, the command defaults to the current
date. If the start time is null, but preceded by a date, the
command defaults to the current time. If the start date
and time are null, the command defaults to the start of the
data. The comma must be present to indicate a null start
time.
= stop time specifies the stop date and time for data
stop
in the format MM-DD,HH-MM. If the date is null but
followed by a time, the command defaults to the current
date. If the stop time is null but preceded by a date, the
command defaults to the current time. If the stop date and
time is null, the command defaults to the end of the data.
There is one line for each data point in the specified time
between start and stop times. Only the number of values
currently available is returned. The maximum stored points
for 100 second time period is 7000; the maximum stored
points for 1000 second time period is 700; the maximum
stored points for 10000 second time period is 70. If a start
and stop time is not specified, the default is current value.
Description
12713020-002-2 Revision D – April 2004