Installing Software; Changing From Subtending Ssu Mode; Files Required For Upgrading The Firmware - Symmetricom SSU-2000 User Manual

Synchronization supply unit and the synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Installing Software

The Subtending SSU requires the software listed in
Table 9-2. Files Required for Upgrading the Firmware
Item Number to
be Upgraded
23413012-000-0
23413012-001-0
23413012-002-0
23413012-003-0
23413015-000-0
23413016-000-0
23413279-000-0
23413158-000-0
To install the software you need to use either the SynCraft application or the
SSU-2000 Download application
Using the SynCraft Application
To use the SynCraft application to install software, refer to the on-line
documentation provided within the program.

Changing From Subtending SSU Mode

To change a Subtending SSU back to the normal mode:
1. Log in to the SSU-2000 and press the Enter key. The system prompt appears.
2. Type
opermode normal
2002-08-15-T15:57:56Z ID: SSU2000 Name: SSU_2000
The SSU2000 is in Normal Mode
3. Type
bye
No hardware changes are necessary.
12713020-002-2 Revision D – April 2004
Description
Comms Module
Stratum 3E Clock Module
Stratum 2 Clock Module
CC Input Module
CC Output Module
and press the Enter key. The system responds with:
and press the Enter key to log off.
Configuring a Subtending SSU
Table
9-2:
File for Module
Firmware Upgrade
01200D00.DN1
01201B00.DN1
01202B00.DN1
01203B00.DN1
01500C00.DN1
01500C00.DN1
27900A00.DN1
15800B00.DN1
Hardware Configuration Guide
File for Module
PLD/FPGA Upgrade
SCOMFPGA.DN9
SCLKFPGA.DN9
SCLKFPGA.DN9
SSUCCINP.DN9
SSUCCOUT.DN9
SSU-2000 User's Guide 231