TL1 Command Interface
Table B-5. TL1 Retrieve Commands (Continued)
Command
RTRV-EVENT-ALARM:[tid]:[aid]:
ctag::[count],[start],[stop];
RTRV-EVENT-REPORT:[tid]:[aid]:
ctag::[count],[start],[stop];
286 SSU-2000 User's Guide
Valid aid code:
,
ALL
SxAy
This command returns only alarm information from the
stored event data.
The format for event log reports is:
^^^"aid:ntfcncde,condtype,srveff,ocrdat,ocrtm:
condscr" <cr lf>
where:
= Notification Code (CR, MJ, MN, CL)
ntfcncde
= Condition Type (event number)
condtype
= service affecting flag (SA, NSA)
srveff
occurrence date
ocrdat
= occurrence time
ocrtm
= condition description string
condstr
= start time specifies the start date and time for
start
data in the format MM-DD,HH-MM. If the date is null but
followed by a time, the command defaults to the current
date. If the start time is null, but preceded by a date, the
command defaults to the current time. If the start date
and time are null, the command defaults to the start of the
data. The comma must be present to indicate a null start
time.
= stop time specifies the stop date and time for data
stop
in the format MM-DD,HH-MM. If the date is null but
followed by a time, the command defaults to the current
date. If the stop time is null but preceded by a date, the
command defaults to the current time. If the stop date
and time is null, the command defaults to the end of the
data.
Valid aid code:
,
ALL
SxAy
This command returns only reports (non-alarm) information
from the stored event data. These have a ntfcncde of NA.
The format for event log reports is:
^^^"aid:ntfcncde,condtype,srveff,ocrdat,ocrtm:
condscr" <cr lf>
where:
= Notification Code (NA)
ntfcncde
= Condition Type (event number)
condtype
= service affecting flag (SA, NSA)
srveff
= occurrence date
ocrdat
= occurrence time
ocrtm
= condition description string
condstr
= the start time
start
= the stop time
stop
Description