Event Messages; Clock Module Event Messages - Symmetricom SSU-2000 User Manual

Synchronization supply unit and the synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Event Messages

Event Messages
Table A-6
lists event messages categorized by module. Each section lists status
messages associated with each module and an event description of each message.
Table A-6. Clock Module Event Messages
Event Message
Install, Clock Module
Remove, Clock Module
Enable, Clock Module, COML\
Disable, Clock Module, COML\
Restart, in 5 seconds, COML\
Cannot Enable, Clock Module, COML\
Clk Select
Software phase lock loop
(Soft PLL, Acquire/Lock/Hold)
Inp Select, 1A04-02\
Output Pql, 2
(PQL value 1 to 5 ST2, or 8 ST3)
CLK C Sel, 1A04-02\
Warmup Chg, 1800 sec, COML\
Start tc, 240, COML\
Dflt tc, 10000, COML\
Clk AR< On, COML\
Inp Switch, AR On, COML\
LO, Dis, COML\
Inp Sel Mode, PQL, COML\
254 SSU-2000 User's Guide
Event #
129
Module installation
130
Module removal
131
Module enabled
132
Module disabled
133
User requesting for a module to reboot
134
Inability to enable module
144
Which clock module is selected to generate
output
145
Software Phase Lock Loop in Acquire, Lock,
or Holdover status
146
An Input has been selected as Reference
147
The Output PQL has been set to the value
shown
148
A reference Input has been selected as an
output source
194
The user has changed the Oscillator
warmup time setting
195
The user has changed the Starting Time
Constant (TAU) of the Oscillator
196
The user has changed the Default Time
Constant (TAU) of the Oscillator
199
The user has changed the Clock
Auto-Return (ON | OFF)
200
The user has changed Input Auto-Return
(ON | OFF)
201
The user has changed the Local Oscillator
Output (ON | OFF) on the LO Output
connector
202
Reference selection mode (Priority Quality
Level – PQL)
Event Description
12713020-002-2 Revision D – April 2004

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdu-2000