RTRV-DATA-MTIE:[tid]:aid:ctag
[::[clksrc][,start][,stop];
280 SSU-2000 User's Guide
Valid aid code:
S1Ay-z
This command returns the MTIE data for an input port. The
command requires an aid to identify the input port to report
data from. It then has the ctag and a null field followed by
optional parameters which contain a clock identifier and the
start and stop times for the measurement. If no clock source
[CLK-A|CLK-B] is specified, the current output clock is used.
The response is the complied message followed by the
requested data. The format for each response message line
is:
^^^"aid:ocrdat,ocrtm,MTIE,clksrc,temper,monval"
<cr lf>
where:
and
= the beginning date and time the data
ocrdat
ocrtm
was collected.
= clock A or B used for the measurements.
clksrc
= time period for the measurement data, given in
tmper
seconds. The maximum tmper values for MTIE are 0.05,
0.1, 1, 10, 100, 1000, 10000, and 100000.
= data value for the time period, given in
monval
nanoseconds.
= start time specifies the start date and time for
start
data in the format MM-DD,HH-MM. If the date is null but
followed by a time, the command defaults to the current
date. If the start time is null, but preceded by a date, the
command defaults to the current time. If the start date
and time are null, the command defaults to the start of the
data. The comma must be present to indicate a null start
time.
= stop time specifies the stop date and time for data
stop
in the format
MM-DD,HH-MM
by a time, the command defaults to the current date. If
the stop time is null but preceded by a date, the
command defaults to the current time. If the stop date
and time is null, the command defaults to the end of the
data.
Only the values available in the interval between the start
and stop times are output.
Description