Interactive Command Set
LRM
Use this command to display the Line Retiming Unit status and settings.
Level 0
Level 1:
Level 2:
Level 3:
Fault
Side 1 LOS
PLL Unlock
Excessive Input
Frequency
Level 4:
Related:
350 SSU-2000 User's Guide
Not applicable
LRM [xAy]
Same as level 1 operation.
Same as Level 2 operation, with the following additions. Use this
command to change the settings of the specified LRM module.
LRM xAy-z[&&z] {ENABLE|DISABLE}
LRM xAy-z[&&z] LBO {133FT|266FT|399FT|533FT|655FT}
LRM xAy-z[&&z] SLIP {CLR|threshold_count}
LRM xAy-z[&&z] BPV {CLR}
LRM xAy-z[&&z] CID {CLR|"circuit_id"}
LRM xAy-z FLT {SQUELCH|AIS}
Options are:
ENABLE/DISABLEEnable/Disable LRM ports
LBO
Line Built-Out
SLIP
Clear SLIP accumulation counter or set 24 hour slip
threshold count
BPV
Clear BPV accumulation counter
CID
Clear or Set Circuit ID
FLT
Defines side 1 output generation when the LRU has a
loss of signal on side 1 input, loss of all reference
sources (PLL unlock), or if the input signal's frequency
has exceeded the LRU's ability to retime data. The
FAULT strategy can be provisioned to AIS or Squelch.
CTA Installed
FAULT
STRATEGY
CTA Engaged
FAULT
STRATEGY
Same as level 3 operation
SETUP, STATUS,
OUTPUT
CTA Not Installed
FAULT
STRATEGY
FAULT
STRATEGY
FAULT
STRATEGY
12713020-002-2 Revision D – April 2004