Symmetricom SSU-2000 User Manual page 371

Synchronization supply unit and the synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Note: Except for the first built-in entry, Read community: 'public' and
Write community: 'private', all user added community strings are
capital cases. Maximum is five SNMP user entries which includes the
built-in user.
Remarks:
Related:
Restrictions: None
12713020-002-2 Revision D – April 2004
Adds the SNMP user "read community" to the system. If
ADD
the user exists in the system this option exits with an
error. After the read community string is entered, this
command prompts for a write community. Write
Community entries are echoed as '*'. Valid write
community characters are all upper alphanumerical
characters. After the write community string is entered,
this command prompts for the user level.
Modifies the write community and/or the access level
MODIFY
for the given user. If the user id is not in the system, this
command exits with an error. Once the user is entered,
this option performs identically to the 'ADD' option.
Deletes the user from system. If the user id is not in the
DELETE
system, this command exits with an error.
Note:
SNMP Manager Table
MANAGER
Initializes the SNMP Manager Table to all null IP
INIT
address
Adds an SNMP Manager IP address into the SNMP
ADD
Manager Table
Deletes an SNMP Manager IP address from the SNMP
DELETE
Manager Table
The length of read community string and write community string
are limited to 10 characters to satisfy TL1 requirements.
USERS
Interactive Command Set
SSU-2000 User's Guide 371