Table B-5. TL1 Retrieve Commands (Continued)
Command
RTRV-DATA-LRMBPV:[tid]:[aid]:
ctag;
12713020-002-2 Revision D – April 2004
Valid aid code:
,
ALL
SxA[y[-z]]
This command returns the BPV data (current operating
mode and status) of an LRM module or port. The format of
response message is:
^^^"aid:ttime,60srate,24hrate,es,ses,sesr" <cr lf>
where:
module
and the port
aid
accumulates how much time (integer) in seconds
ttime
since the last BPV Clear command was issued
= BPV error rate (float value) per second in a
60srate
60-second window
= BPV error rate (float value) per second in an
24hrate
86400-second window
indicates (integer) that the BPV accumulates BPV
es
Errored Seconds (BPV-ES) when any seconds have a
BPV error
indicates (integer) that the BPV accumulates BPV
ses
Severely Errored Seconds (BPV-SES) when any
seconds have a severely BPV error
= BPV Severely Errored Ratio (float value).
sesr
TL1 Command Interface
Description
SSU-2000 User's Guide 279