Setting Subtending Parameters - Symmetricom SSU-2000 User Manual

Synchronization supply unit and the synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Output modules are available to support the following formats:
DS1, SF (D4) and ESF
E1, CAS, and CCS
2048 kHz
Composite Clock (CC) (64/8 kHz)
Other typical clock frequencies

Setting Subtending Parameters

The SSU-2000 software includes the following new command that allows you to
enable and disable the Subtending mode. For additional information on general
syntax and usage, refer to
OPERMODE
This command allows you to view and change the operating mode of the
SSU-2000.
Level 0
Level 1
Level 2
Level 3
If you do not specify a parameter, the system displays the current mode.
Level 4
Restrictions
12713020-002-2 Revision D – April 2004
Appendix B, Communications
Not applicable
Not applicable
Not applicable
OPERMODE [SUBTENDING|NORMAL]
Sets the SSU to Subtending mode.
SUBTENDING
Sets the SSU to normal TSG operation.
NORMAL
Same as Level 3 operation.
See
Changing to Subtending SSU
hardware and software requirements.
Hardware Configuration Guide
Configuring a Subtending SSU
Protocol.
Mode, on page 230, for
SSU-2000 User's Guide 229