Table B-6. TL1 Set Commands (Continued)
Command
SET-PRMTR-OUTPUT:[tid]:[aid]
:ctag::[pstate],[mode],
[level],[bypass],[zs],[crc],
[len],[bit];
SET-PRMTR-PBO:[tid]::ctag::
pbo_mode;
SET-PRMTR-SETUP:[tid]:[aid]:
ctag::[factory| user|save];
SET-PRMTR-SNMP-MODE:[tid]::
ctag::[mode], [trap_filter];
12713020-002-2 Revision D – April 2004
Valid aid code:
,
ALL
SxA[y[-z]]
This command sets the output port parameters.
where:
= enabled or disabled [ON|OFF]
pstate
= signal mode [ESF|D4|CCS|CAS]
mode
= outputs are turned on [WARM |ACQ |LOCK]
level
For framed outputs:
= zero suppression
zs
= error checking [ON|OFF]
crc
= line length setting of [133|266|399|533|655] feet for
len
DS1 outputs
= ssm bit [4| through [8] for E1 sync status messages
bit
= allow Clock C selection [ON|OFF]
bypass
Setting the status for a module (no port –z) sets all ports
[ON|OFF]. Empty fields leave parameters unchanged.
Valid aid code: none
The pbo_mode is [DIS| EVT| REP| NONE].
disables the phase buildout (PBO) function.
DIS
enables the PBO function. The PBO event is
EVT
displayed and stored in the COMM module event buffer.
enables the PBO function. The PBO event is
REP
displayed, but the event is not stored in the COMM
module event buffer.
enables the PBO function. The PBO event is neither
NONE
displayed nor stored in the COMM module event buffer.
Valid aid code:
,
ALL
SxA[y[-z]]
This command sets or saves the configuration of the specified
module.
restores the module configuration to factory defaults.
Factory
Any time the configuration has changed from the factory
configuration, these configurations become the current
configurations.
stores the current configuration.
Save
The
parameter reloads the previously saved configuration.
user
Valid aid code: None
This command sets the SNMP mode and trap filter parameters.
Values for
are as follows:
mode
Enables SNMP operation in the system
ENA
Disables SNMP operation in the system
DIS
Values for
trap_filter
Only alarms cause Traps to be transmitted
ALM
All events and alarms cause the transmission of Traps
ALL
Empty fields leave parameters unchanged.
TL1 Command Interface
Description
are as follows:
SSU-2000 User's Guide 311