Interactive Command Set
PHASE
Use this command to access phase history data.
Level 0
Level 1
Example:
SSU_2000->phase
The current phase values with T1:
1A03-01
1A04-01
1A04-02
1A04-03
1A05-01
1A09-01
1A09-02
1A09-03
1A10-01
1A10-02
1A10-03
1A11-01
1A11-02
1A11-03
Level 2
Level 3
Level 4
Remarks
Related
Restrictions None
360 SSU-2000 User's Guide
Not applicable
PHASE [xAy[-z]][{A|B}]{T1|T100|T1K|T10K}[count]
Use this command to view the 100/ 1,000/ 10,000 seconds phase
history information. One second phase is not stored in phase
history. If you do not provide a parameter, phase information
displays for the selected clock to all inputs that last stored the
point.
PhA:2001-05-24T18:29:00, 3
PhA:2001-05-24T18:29:09, 1
PhA:2001-05-24T18:29:09, 1
PhA:2001-05-24T18:29:09, 3
PhA:2001-05-24T18:29:12, 5
PhA:2001-05-24T18:29:12, 1
PhA:2001-05-24T18:29:12, 2
PhA:2001-05-24T18:29:12, NA
PhA:2001-05-24T18:29:13, 1
PhA:2001-05-24T18:29:13, 3
PhA:2001-05-24T18:29:13, 2
PhA:2001-05-24T18:29:14, NA
PhA:2001-05-24T18:29:14, 2
PhA:2001-05-24T18:29:14, NA
Same as Level 2 operation, with the following additions:
PHASE [xAy[-z]] ZERO [{A|B}]
Use this command to zero the phase error for the desired input
port. If you do not provide a parameter, all inputs on both clocks are
zeroed.
Same as Level 2 operation
Same as Level 3 operation
None
STATUS,
INPUT
12713020-002-2 Revision D – April 2004