Symmetricom SSU-2000 User Manual page 292

Synchronization supply unit and the synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

TL1 Command Interface
Table B-5. TL1 Retrieve Commands (Continued)
Command
RTRV-PRMTR-CLKOUT:[tid]:[aid]:
ctag;
292 SSU-2000 User's Guide
Valid aid code:
,
ALL
SxAy[-z]
This command returns the output port setting when a port
aid is specified.
The format for the response message is:
^^^"aid:mode,level,bypass,fltmode,pstate,
squelch" <cr lf>
where:
= module access identifier
aid
= CLK
mode
= [WARM|ACQ|LOCK] for the clock level where
level
outputs are turned on,
= allow Clock C selection: [ON|OFF]
bypass
= determines if outputs are set to fault [OFF|
fltmode
ON|AUTO] when signal levels drop below the threshold
output level
= port state [1|0] (where 1 = ON and 0 = OFF).
pstate
= threshold value [0|1|...|16] (where 0 =
squelch
disabled). If the reference clock PQL exceeds this value,
then the output is turned off.
When no port is specified by the aid, then the response is
two lines as follows:
^^^"aid:mode,level,bypass,fltmode" <cr lf>
^^^"aid:pstate1,pstate2,...,pstate20" <cr lf>
^^^"aid:squelch1,squelch2,...,squelch20" <cr lf>
where:
Line 1 contains:
= CLK
mode
= [WARM|ACQ|LOCK] for the clock level where
level
outputs are turned on,
= [ON|OFF] for allowing Clock C selection
bypass
= determines if outputs are set to fault [OFF|
fltmode
ON|AUTO] when signal levels drop below the threshold
output level
Line 2 contains:
= access identifier of module
aid
= port state [1|0] 1 = ON and 0 = OFF, and # =
pstate#
port number 1 through 20
Line 3 contains:
= access identifier of module
aid
= squelch value [0|1...|16] and # = port number
squelch#
1 through 20
Description
12713020-002-2 Revision D – April 2004

Advertisement

Table of Contents
loading

Related Products for Symmetricom SSU-2000

This manual is also suitable for:

Sdu-2000