Table B-6. TL1 Set Commands (Continued)
Command
SET-PRMTR-LRM:[tid]:[aid]:
ctag::[enable],[lbo],
[slip],[bpv],[flt];
SET-PRMTR-LRMCID:
[tid]:[aid]:ctag::[cid];
SET-PRMTR-MTIE:[tid]:[aid]:
ctag::{EL1|EL2|CL1|CL2},
[t10],[t100],[t1k],[t10k],
[t100k];
12713020-002-2 Revision D – April 2004
Valid aid code:
,
ALL
SxA[y[-z]]
This command sets the LRM port
= {ON|OFF} for enabled or disabled
enable
= line build-out setting in feet {133|266|399|533| 655} for
lbo
DS1 outputs
= {0|1–255} allows you to set the slip error threshold in
slip
any 24 hour period. If the value is zero, the slip accumulated
error counts are cleared.
= {CLR|NOP}. CLR clears the BPV error count and
bpv
accumulated error ratio. NOP is an empty field with no
operation
= {AIS|SQUELCH}. It defines side 1 output generation
flt
when the LRU has a loss of signal on side 1 input, loss of all
reference sources (PLL unlock), or if the input signal's
frequency has exceeded the LRU's ability to retime data.
Fault
CTA Installed
Side 1 LOS
FLT STRATEGY
PLL Unlock
CTA Engaged
Excessive Input
FLT STRATEGY
Frequency
Valid aid code:
,
ALL
SxA[y[-z]]
This command sets the LRM port circuit id (CID). CID is a 0 to
43 character string with all ASCII printable characters.
Valid aid code:
,
ALL
S1Ay[-z]
This command sets the input MTIE alarm thresholds EL1or
EL2 and the clear thresholds CL1 or CL2 for the designated
input.
Threshold settings t10 through t100k are the error limits in
nanoseconds for the measurement time period.
With the aid of ALL (or null) the specified parameters are set
for all inputs.
TL1 Command Interface
Description
CTA Not Installed
FLT STRATEGY
FLT STRATEGY
FLT STRATEGY
SSU-2000 User's Guide 309