Table B-6. TL1 Set Commands (Continued)
Command
SET-PRMTR-CLKOUT:[tid]:[aid]
:ctag::[pstate],[mode],
[level],[bypass],[fltmode];
SET-PRMTR-COMM:[tid]:[aid]:
ctag::[baud],[echo],[eol],
[mode],[tout];
SET-PRMTR-ELTIME:[tid]:[aid]
:ctag::elevtime;
SET-PRMTR-FREQ:[tid]:[aid]:
ctag::[fae],[fac],[fbe],
[fbc];
SET-PRMTR-GPS:[tid]:[aid]:
ctag::pri],[pql],[sigma];
12713020-002-2 Revision D – April 2004
Valid aid code:
,
ALL
SxA[y[-z]]
= sets output port state: [ON|OFF]
pstate
= ignored
mode
= set the clock mode: [WARM|ACQ|LOCK]
level
= allow Clock C selection [ON|OFF] when outputs
bypass
are turned on
= allow output level to be monitored for fault
fltmode
thresholds: [OFF|ON|AUTO]. Omitting the port aid (no
in the aid sets all ports on the module to [ON|OFF].
Empty fields leave parameters unchanged.
Valid aid code:
,
ALL
COML
where:
= set the communication port [ALL|COML|COMA|
aid
COMB]
= set the communications baud rate [19200|9600|
baud
4800|2400|1200]
= set unit to use full or half duplex [ON |OFF]
echo
= set end-of-line character(s) sent by the unit [CR| LF|
eol
CRLF]
= set the mode of communication to [ASCII|TL1]
mode
= set the inactivity timeout period [5 – 43200| NEVER]
tout
Valid aid code:
SxAy
This command sets the time for alarm elevation, from 60
seconds to 500,000 seconds. A setting of 0 (zero) means no
elevation for the alarm. When an alarm has been at MINOR
or MAJOR level continuously for ELTIME seconds, then it is
elevated to the next level.
This may be set for each module or ALL modules, and
applies to all alarms created by the module.
Valid aid code:
,
ALL
S1Ay[-z]
This command sets the input Frequency alarm thresholds.
= error threshold for input versus A clock
fae
= clear threshold for input versus Clock A
fac
= error threshold for input versus B clock
fbe
= clear threshold for input versus Clock B, for the
fbc
designated input
The maximum settings for these limits is 10 000 000 in units
of ps/s. Empty fields are unchanged.
Valid aid code:
or
S1A3
= set the priority setting of [0 through 10, with 0 = MON]
pri
= set the priority quality level [1 through 16]
pql
= set the limit of the noise measurement
sigma
[10 to 1000 µs]
TL1 Command Interface
Description
,
,
,
, or
COMA
COMB
TELNET
(for a unit with GPS module)
S1A5
SSU-2000 User's Guide 307