Symmetricom SSU-2000 User Manual page 312

Synchronization supply unit and the synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

TL1 Command Interface
Table B-6. TL1 Set Commands (Continued)
Command
SET-PRMTR-SNMP-MANAGER:[tid]
::ctag::mode,[ip];
SET-PRMTR-SNMP-USER:[tid]::
ctag::mode,[rd_community],
[wr_community], [level];
SET-PRMTR-SNMPV3-MANAGER:
[tid]::ctag::mode,[ip],
[username];
SET-PRMTR-SNMPV3-
NOTIFICATION:[tid]::ctag::
[notification];
312 SSU-2000 User's Guide
Valid aid code: none
This command allows changes to the SNMP manager table
entries.
= {ADD| DEL| INIT}
mode
where:
requires an IP address
ADD
only requires an IP address to delete the entry from
DEL
the table
requires no additional parameters and clears all
INIT
entries in the table
Valid aid code: none
This command allows changes to the SNMP security of the
system.
= {ADD| DEL| MOD| INIT}
mode
where:
requires a
ADD
rd_community
defaults to 1 if not entered
Level
only requires a username to delete the user from the
DEL
table
requires a username, a new password, and new user
MOD
level
requires no additional parmeters and clears all
INIT
entries in the table
Valid aid code:
none
This command allows changes to the SNMPv3 manager table
entries.
mode = {ADD|DEL|MOD|INIT}
where:
ADD requires an IP address and username
DEL requires an IP address to delete the entry from the
table
DEL requires an IP address to key the entry and modify its
username in the table
INIT requires no additional parameters and clears all
entries in the table
Valid aid code:
none
This command sets the SNMP v3 notification type.
= {V2|V3|ALL} to set SNMP notification to
notification
SNMPv2, SNMPv3, or both types when an event occurs
Description
and
wr_community
12713020-002-2 Revision D – April 2004

Advertisement

Table of Contents
loading

Related Products for Symmetricom SSU-2000

This manual is also suitable for:

Sdu-2000

Table of Contents