Field Service Ver2.0 Aug.2005
3.9
Maintenance procedure of the transfer/separation unit
3.9.1
Replacing the transfer/separation unit
•
Transfer/separation unit: Every 6,000,000 prints
[2]
[1]
[1]
57gaf2c069na
[2]
[3]
57gaf2c070na
1.
2.
3.
Loosen 2 screws [1] and remove the transfer/sep-
aration unit [2].
Note
• Reinstall the transfer/separation unit [1] so
that the couplings [2] and [3] engage cor-
rectly.
4.
3. PERIODIC CHECK