Konica Minolta bizhub PRO 920 Service Manual page 210

Main body
Hide thumbs Also See for bizhub PRO 920:
Table of Contents

Advertisement

3. PERIODIC CHECK
B. Installation procedure
[5]
[2]
[3]
[4]
[7]
178
[1]
[2]
[6]
a
[8]
57gaf2c035na
Field Service Ver2.0 Aug.2005
1.
Reassemble the thermistor /1 assembly.
2.
Install 2 fastons [2] to the thermostat /1 assembly
[1].
3.
Insert the thermostat positioning jig (55VAJG031)
[4] between the thermostat /1 (TS1) and the fus-
ing roller /Up [3].
4.
Adjust the position of the TS1 so that it become
flush
with
the
thermostat
(55VAJG031) , and then fix it with the screw [5].
Note
• Be sure to adjust the distance a [8] between
the TS1 and the fusing roller /Up [7] so that it
becomes equal to the thickness of the ther-
mostat positioning jig (55VAJG031).
Specified value: a = 3.0 ± 0.2mm
5.
Apply Screw-lock to the screw [5].
6.
For the parts to be reinstalled hereafter, reinstall
them following the removal steps in reverse.
positioning
jig